Pentair P4 Benutzerhandbuch

Seite von 32
Page 15
3.4 Heater 
Connection
The heater connection section applies to all 
heaters or heat pumps with thermostatic circuitry 
of 24 VAC or less (see pages 15 thru 17 for brand 
specific installation).
NOTE  If you are connecting a heater with thermostatic 
circuitry of 120 VAC or greater, do not connect 
to the green, 10-pin Terminal Bar. Instead, 
connect the heater to a high voltage relay in 
the Power Center and plug the spare relay into 
the Electric Heater relay socket located on the 
upper right hand corner of the Power Center 
PCB.
3.4.1  Jandy Brand Heater Connections
1. 
Connect two #14 gauge wires, designed for 
use in hot en vi ron ments, to the #1 and #2 
terminals on the green, 10-pin Terminal Bar.
2. 
Connect the other ends of the #14 gauge 
wires from Step 1 to the Fireman's Switch 
terminal bar in place of the factory installed 
wire loop. 
3. 
Do not disconnect high limit or pressure 
switches.
4. 
Turn the heater thermostat(s) to maximum 
setting.
5. 
Turn the heater switch to the ON position. 
For dual thermostat heaters turn switch to 
Spa position.
Figure 9. 
Lite2 Heater Connection
Power Center PCB/Bezel
Heater 
Wiring
#14 
Gauge 
Wire
Green 10-pin 
Ter mi nal Bar
Heater 
Ther mo stat To 
Max.
Heater Toggle 
Switch To On
Terminal 1
Terminal 2
Heater Fireman's Switch 
Con nec tion
Factory 
Installed
Wire Loop
3.4.2  Guidelines for Sophisticated Diagnostic 
Communication to LX Heaters
1. 
Remove the LX GUI from the heater.
2. Confi rm the LX and AquaLink RS software 
revisions are compatible (see table).
3. 
Run a 4-conductor cable from the LX GUI 
red, 4-pin connector to the RS power Center 
red, 4-pin connector (see Figure 10).
LX Software Revision
AquaLink RS Software 
Revision
C10, C11 or later
PDA 1.0 or later
NOTE  If connecting more than two (2) items to the RS 
Power Center red, 4-pin con nec tor, a Multiplex 
PCB is required.
OPTIONAL
4 3 2 1
4321
RED
BLK
YEL
GRN
RED
BLK
YEL
GR
N
4-Conductor 
Wire 
LX GUI
RS Power 
Center
Figure 10.  LX Heater Connection to Power Center
PDA
J-box
3.4.3  Other Brands Heater Connections
To set up heater connections on heaters 
manufactured by Hayward, Pentair, and Raypak, 
please refer to the Installation Manual provided 
with these heaters.