3.5 Temperature 
Sensors
1. 
Drill 3/8" hole in pipe between fi lter 
pump and fi lter and install the Water 
Temperature Sensor
 per instructions 
(make certain the o-ring is in place).
2. Install 
Air Temperature Sensor outside the 
Power Center can, not in direct sunlight and 
away from motors and other heat sources.
3. Install 
Solar Temperature Sensor 
(optional) adjacent to solar panels. 
4. 
Run the wire to the Power Center, through 
the low voltage raceway. Cut off excess 
wire. Strip the wire jacket back 6", then 
strip each wire ¼". Connect sensor wires to 
the green, 10-pin terminal bar (see 
Figure 17).
3.6 Jandy 
Valve 
Actuators
NOTE  Mount the JVAs according to the Jandy Valve 
Actuator Installation and Operation Manual.
JVA cable is type SJW-A marked water resistant 
class 3 cable and does not require conduit. 
Knockouts and Heyco fittings are provided in the 
Low Voltage Raceway.
1. 
Route the JVA wire to the Power Center.
2. 
Run the wire through the low voltage 
raceway and plug the JVA connectors into 
their proper sockets (see Section 6. Power 
Center Wiring Diagram
). Verify that the 
JVA on the suction plumbing is connected 
to the Intake JVA Socket, and the discharge 
plumbing is connected to the Return JVA 
Socket.
Figure 17.  Temperature Sensor Wiring for a Pool/
Spa Combination
Water 
Temperature 
Sensor
Freeze/Air 
Temperature 
Sensor
Solar 
Temperature 
Sensor
Green 10-Pin Terminal Bar
10 9 8 7 6 5 4 3 2 1
NOTE  Do not coil the JVA wires inside Power Center. 
To shorten the wire, remove the JVA cover 
and disconnect the wire. Shorten, strip, and 
reconnect. 
3. 
For alternate plumbing confi gurations the 
JVA cam settings can be adjusted as needed. 
See the Jandy Valve Actuator Installation 
and Operation Manual, Cam Setting Chart 
for proper settings.
3.7 
PDA Transceiver J-box Installation
Installation Considerations. The transceivers will 
transmit through walls and around corners. Steel 
framing, aluminum siding, wrought iron, cyclone 
fences, lead ed glass, and other 900 MHz frequency 
items  may  inhibit/prevent  com mu ni ca tion  between 
the AquaL ink RS PDA Handheld Remote and the 
Power Center. The trans ceiv ers do not require 
line of sight to communicate. 
To optimize 
communication, install trans ceiv ers in a location 
that minimizes interference. 
3.7.1  Outdoor Transceiver J-box Installation 
1. 
Turn off all power to the Power Center. 
2. 
Mount the Outdoor Transceiver J-box at 
least 6' above the ground and at least 8' 
from an air blower (see Figure 18). 
NOTE  To improve performance of the transceiver, 
mount the J-box more than 6' above the ground.
3. 
Open the door to the Power Center and 
remove the dead panel.
4. 
Feed the four conductor wire into the Power 
Center through the low volt age raceway.
5. 
Cut off the excess wire. Strip the jacket 
back 6" and strip the individual wires 
approximately ¼". Connect the four 
conductor wire to the red terminal bar on 
the Power Center PCB.
6. 
Install the dead panel to the Power Center 
and restore all power.