Cleaning the Headgear Assembly 
Use a soft cloth to remove dirt and grime. If the headgear requires further cleaning, remove the motor 
housing assembly, the head harness assembly, the head seal assembly, the visor assembly, the main 
filter, and the expander. Only the headgear shell may be immersed in a mild solution of soap and water. 
Rinse the visor assembly with clean running water to remove dirt and shake off the excess water. 
Handle the visor carefully to avoid unnecessary scratching. Allow all components to dry thoroughly 
before reassembling.
Cleaning the Head Harness Assembly (Headband, Comfort Band, Cradle Assembly) and Head 
Seal Assembly (Head Seal, Temple Seal)
Wipe with a cloth dampened with a solution of mild soap and water. Wipe off excess water 
and allow to dry prior to reinstallation.
Cleaning the Motor Housing Assembly
In some environments, dust may gradually accumulate within the motor housing, which could reduce 
the efficiency of the motor unit. The accumulated dust can be removed by first removing the prefilter 
from its compartment and then using a vacuum cleaner to clean the prefilter side of the motor 
housing. Do not use a vacuum or compressed air to force air directly through the motor/fan assembly. 
This may cause the motor to spin too fast and damage the motor’s bearings.
After cleaning the system, inspect all parts for damage and wear, replacing parts if necessary. Allow 
the components to dry completely, away from sunlight and direct heat. Store the system in a clean 
area, away from moisture, heat, and direct sunlight. Storage temperatures must not exceed 120°F 
(49ºC).
Storage
Store your respirator at room temperature in a dry area that is protected from exposure to hazardous 
contaminants.
TROUBLESHOOTING
Leave contaminated area immediately and follow these corrective action recommendations. Use the 
table below to help identify possible causes.
Problem
Possible Cause
Corrective Action
Poor visibility 
through faceshield
Faceshield is scratched.
Faceshield is coated with debris.
Faceshield is fogging.
Remove cover and replace.
Wipe debris off.
Replace visor.
Consider using faceshield covers.
Check airflow.
Install a new anti-fog visor AS-131.
Switch to motor housing assembly, 
ultra AS-115 (AS-400 and AS-600 only).
Poor airflow
Battery discharged or worn out.
Filter and/or prefilter is clogged.
Filter/cartridge holder is damaged, 
installed incorrectly, backwards or 
not installed.
Incorrect filter/cartridge holder 
installed.
Filter sleeve out of position or inside 
motor housing.
Charge, service or replace.
Replace filter with new filter.
Remove and re-install as directed.
Replace if neccessary.
Use new holder for HE filter.
Remove blower housing and re-install 
as directed.
Faceseal not fitting 
tightly against face
Damaged or worn faceseal.
Cradle assembly not adjusted 
properly.
Replace Faceseal.
 Adjust as directed.
Dust getting inside 
visor
Filter sleeve out of position or inside 
motor housing.
Filter torn during installation.
Filter not installed.
Remove blower housing and re-install 
as directed.
Replace with new filter.
Install filter as directed.