3M 2250M-iD User Manual

Page of 66
 30 
78-8130-6150-0 Rev G
D. Induction Peak (Ind Pk)
Locate/OK [5] + Cable/Pipe [SK] + Mode [SK] + Ind Pk [SK Toggle]
If you cannot make a direct connection, or use the 3M
™ 
Dyna-Coupler Clamp to apply 
a locating signal on the target, use the induction method. This method uses the internal 
coil of the transmitter to generate a magnetic field.
The Induction Peak mode of the receiver is a mode in which the upper antenna of the 
receiver is tuned to minimize distortion from the magnetic field of the transmitter.
Left or Right of Target Path
Directly Over Target Path
E. Expanded Mode
When the third ring of the speaker icon is dotted 
or broken and ‘xpnd’ appears below the speaker 
icon as shown, the receiver is in “Expanded” 
mode. This mode is used for pinpointing a 
target cable or pipe. The area of response of 
the receiver narrows, allowing the locator to 
detect very small signal changes. Press the 
Speaker Volume Control [2] key to activate the 
"Expanded" mode.
8. Depth and Current Estimate
Verifying the target path, depth and current can be helpful tools.
1.  Pinpoint the cable or pipe being located.
2.  Lower the tip of the receiver to the ground and 
press Depth [SK].
 
− The depth to the target cable or pipe is 
displayed in the units specified in the receiver 
set up menu. The bold current reading is a 
relative current measurement. This reading 
can be compared to the current reading that 
alternately flashes with the frequency on the 
transmitter to help identify the target cable/
pipe. The highest relative current value will 
be the target cable/pipe and will compare 
closest to the transmitter relative current value. 
The milliamp reading is an actual current 
measurement.