Alliance Laundry Systems TMB795C User Manual

Page of 63
Installation
M414905
28
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 12 
How to Change Burner Orifice Size
1. Disconnect electrical power from tumbler. Close 
gas shut-off valve to tumbler. Refer to Figure 11.
2. Remove spud holder.
Johnson G96 Gas Valve – Unscrew spud holder 
nut near gas valve. Remove the burner orifice(s) 
from spud holder. Refer to Figure 12.
3. Install the new, correct burner orifice(s). Refer to 
Figure 13 and Table 1Torque each to 9 – 10 Nm.
4. Reinstall spud holder assembly to gas valve, 
making certain burner orifice(s) are in line with 
burner tube opening. Refer to Figure 13.
5. Commission tumbler for use.
NOTE: Blank burner orifices are Part No. 
M400995.
TMB1527N
1
Burner
8
Anti-Torque Ring
2
Gas Valve
9
Manifold Pipe
3
Regulator Plate
10
Spud Holder 
4
Gasket
11
Pressure Tap
5
Plate
12
Burner Orifice
6
Regulator Cap
13
Burner Tube Openings
7
Spud Holder Nut
1
10
9
8 7
6
5
4
3
2
11
13
12