Programming the Electronic OPL Control
Figure 9 
Drying can be done automatically or by time dry. 
When drying automatically, the tumbler stops drying 
when laundry reaches the factory set or programmed 
dryness level and starts cool down. When time drying, 
the tumbler stops drying when programmed time ends 
and starts cool down.
Both automatic and time dry have factory-set cycles, 
but other cycles can also be created. Frequently used 
cycles can be saved in the control’s memory as Custom 
cycles. 
In all cycles, except No Heat, Wrinkle-Free begins 
when Cool Down ends. During Wrinkle-Free, the 
tumbler alternately stops for 2-1/2 minutes and then 
runs without heat for 2-1/2 minutes until door is 
opened or 60 minutes has elapsed.
The HIGH, MEDIUM, MED LOW, and LOW ON/
SELECT pads may be saved in one of four ways as a 
custom heat cycle, refer to Table 1.
Table 1 
T359I
NOTE: Not all tumblers will have reversing option.
STATUS
DRYING
COOL DOWN
DOOR OPEN
CUSTOM
HIGH
MEDIUM
MED LOW
LOW
NO HEAT
TEMP
DISPLAY
SIGNAL
F/ C
TEMP
PROGRAM
AUTO
SPECIAL
CYCLE
MORE
CONDITION
SPECIAL
TIME
COOL
 DOWN
LESS
SAVE
CUSTOM
TIME
*
+
-
-
*
PROG
AUTO
AUTO
ON / SELECT
START
STOP/RESET
REVERSING
T359I
One pre-programmed 
NO HEAT cycle
Four pre-programmed 
Automatic Dry heat 
cycles
All of these cycles 
may be used as 
pre-programmed 
from the factory . . .
They may be 
modified for one 
cycle without 
being saved in 
the memory . . .
They may be 
modified and 
saved in the 
memory as one of 
five CUSTOM 
CYCLES.
OR
OR
Custom Cycles
Automatic Dry
Dries the load to one of eleven user-
selectable dryness levels for a given 
fabric type, and then enters automatic 
or user-variable cool down.
Time Dry
Duplicates the functions of 
electromechanical dual timer 
controls, allowing the user to vary 
temperature, drying time and cool 
down time.
Special Cycle
Allows the user to specify the 
number of heating cycles and to 
select from the full range of 
temperatures for all heat cycles.
Special Time
Similar to Time Dry, except that the 
user may specify from 80°F (27°C) 