Pressure checks can be made at the shut-off valve 
(refer to Figure 14). 
Turn on gas and check all pipe connections (internal 
and external) for gas leaks with a non-corrosive leak 
detection fluid. 
Purge air in gas service line by operating the tumbler 
in the drying mode. 
If burner does not light and unit goes into lockout, 
open and close the door and restart. Repeat these steps 
until burner ignites. Use pipe compound, resistant to 
actions of L.P. Gas, on all pipe threads.
WARNING
Check all pipe connections, internal and 
external, for gas leaks using a non-
corrosive leak detection fluid. To reduce 
the risk of explosion or fire, DO NOT USE 
AN OPEN FLAME TO CHECK FOR GAS 
LEAKS! Gas connections should be 
checked annually for leakage.