FACILITIES REQUIRED
To assure compliance, consult local building code 
requirements.
FLOOR
The tumbler must be installed on a level floor capable of 
supporting 100 pounds per square foot (488.3 kg/sq. m). 
Floor covering materials such as carpeting or tile must be 
removed.
LAYOUT
Whenever possible, tumblers should be installed along an 
outside wall where duct length can be kept to a minimum, 
and make-up air can be easily accessed.  Construction 
must not block the airflow at the top rear of the tumbler.  
Doing so would prevent adequate air supply to the 
tumbler’s combustion chamber.
VENTING
For maximum efficiency and minimum lint 
accumulation, tumbler air must be exhausted to the 
outdoors by the shortest possible route.
Proper sized exhaust ducts are essential for proper 
operation.  All elbows should be sweep type.  Exhaust 
ducts must be assembled so the interior surfaces are 
smooth, so the joints do not permit the accumulation of 
lint.  Do not use sheet metal screws to join vent sections.  
Improperly sized or assembled ductwork causes excess 
back pressure which results in slow drying, lint collecting 
in the duct, lint blowing back into the room, and 
increased fire hazard.
Exhaust ducts shall be constructed of sheet metal or 
other noncombustible material. Such ducts must be 
equivalent in strength and corrosion resistance to 
ducts made of galvanized sheet steel not less than 
0.0195 inches (0.495 mm) thick.
Where the exhaust duct pierces a combustible wall or 
ceiling, an opening having a diameter of 4 inches (10.2 
cm) larger than the diameter of the exhaust duct shall be 
provided, with the duct centered in the opening.  When 
ducts pass through walls, ceilings, floors or partitions, the 
space around the duct shall be sealed with non-
combustible material.  Refer to Figures 3, 4 and 5. 
• Individual Venting
For maximum efficiency and performance, it is 
preferred to exhaust tumbler(s) individually to the 
outdoors.  At no point may the cross area of installed 
venting be less than the cross area of the exhaust 
thimble of the tumbler.
The maximum allowable length venting is 14 feet (4.3 
m) and two 90° elbows or equivalent. If the equivalent 
length of a duct required for an installation exceeds the 
maximum allowable equivalent length, the diameter of 
a round duct must be increased by 10% for each 
additional 20 feet (6.1 m). Cross section area of a 
rectangular duct must be increased by 20% for each 
addtional 20 feet (6.1 m). To determine equivalent 
venting, Refer to Table 1.
Table 1
Example:  A 12" diameter duct’s equivalent 
length of 14 feet of duct and two 90° elbows is:
Equivalent Length = 14 feet + (2) 90° elbows
= 14 feet + 14 feet + 14 feet
= 42 feet (12.8 m)
With the tumbler in operation, airflow at any point in 
the duct must be at least 1200 feet per minute (366 m./
min.) to insure that the lint remains airborne.
A drying tumbler produces combustible 
lint. To reduce the risk of fire, the tumbler 
must be exhausted to the outdoors.
W057
WARNING
DUCT 
DIAMETER
EQUIVALENT LENGTH OF 
STRAIGHT DUCT
  6" (15.2 cm)
  8" (20.3 cm)
10" (25.40 cm) 
12" (30.48 cm)
14" (35.56 cm)
16" (40.64 cm)
18" (45.72 cm)
One 90° elbow = 7 feet (2.1 m)
One 90° elbow = 9.3 feet (2.83 m)
One 90° elbow = 11.6 feet (3.5 m)
One 90° elbow = 14 feet (4.3 m)
One 90° elbow = 16 feet (4.9 m)
One 90° elbow = 18.7 feet (5.7 m)
One 90° elbow = 21 feet (6.4 m)
Equivalent Length (feet) = 1.7 x Duct Diameter 
(inches)