Alliance Laundry Systems 000 BTU User Manual

Page of 144
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
66
M414545
MONTHLY
LUBRICATION
Motor bearings, idler housing bearings and trunnion 
bearings are pre-lubed sealed bearings and require no 
lubrication.
LINT REMOVAL
1. Remove the exhaust duct from the exhaust thimble 
and remove lint. If excessive lint is evident at the 
thimble, further disassemble the duct work and 
remove lint.
2. On Energy Saver Gas Models:
Remove the cleanout cover at the bottom of the 
vertical duct and clean out lint.
EVERY THREE MONTHS
LINT REMOVAL
1. Clean the lint and any other foreign materials from 
the air vents located on the front and back of the drive 
motor. The drive motor is air cooled and if the air 
vents become clogged, the motor will overheat and 
the internal thermal overload protector will cycle off.
2. Steam Models: Check the steam coils and remove 
any lint buildup and/or replace air filter in the coil fin 
area. This can be accomplished by using compressed 
air or by fabricating a comb that can be pulled across 
the fin area of the coil.
3. Exhaust ducts should be periodically inspected to 
ensure there has been no buildup of lint which could 
obstruct the airflow.
4. Inspect the dryer area to make sure nothing is 
obstructing the flow of combustion and ventilation 
air.
5. Remove front panel and clean any lint buildup.
BELT TENSION
Check belt tension and adjust if needed. Refer to 
appropriate section.
EVERY SIX MONTHS
OVERALL CHECK
Check the tumbler over thoroughly for loose nuts, bolts 
and screws, and for loose gas, steam and/or electrical 
connections.
GAS CONNECTIONS: (Unions, flared tube fittings) 
Check for leakage that might be caused by vibration. Use 
a mild soap solution. DO NOT USE A FLAME AT 
ANY TIME TO CHECK FOR GAS LEAKS.
ELECTRICAL CONNECTIONS: Electrical service and 
grounding connections should be examined for proper 
tightness.
To reduce the risk of serious injury or 
death, disconnect the power to the 
tumbler before performing this operation.
W080
WARNING
To reduce the risk of serious injury or 
death, disconnect power to the tumbler 
before performing these operations.
W081
WARNING
To reduce the risk of serious injury or 
death, disconnect the power to the 
tumbler before performing this operation.
W080
WARNING