ENERGY SAVING TIPS
1. Install the tumbler so that short, straight venting can 
be used.  Turns, elbows and long vents tend to 
increase drying time.  Longer dry time means the use 
of more energy and higher operating costs
.
2. Operate tumbler using full-size loads.  Overloading 
uses extra energy.  Very small loads waste energy.
3. Dry lightweight fabrics separately from heavy 
fabrics.  Less energy will be used and drying results 
will be more even if the fabrics being dried are of 
similar weight.
 
4. Clean the lint screen after each eight hour shift.  A 
clean lint screen helps give faster, more economical 
drying.
5. Do not open the loading door while drying.  Warm air 
will escape into the room.
6. Unload the tumbler as soon as the cylinder stops or 
when LOAD READY light illuminates.
IMPORTANT: The input ratings shown on the serial 
plate are for units that are being operated at 
elevations up to 2,000 feet (610 m).  If the tumbler is to 
be operated above 2,000 feet (610 m), contact 
distributor for proper gas orifices for your altitude.
SERVICE SAVERS
The following are some of the most common problems, 
along with the solutions, that occur with a tumbler.  
Before contacting the Service Department, perform these 
procedures:
TUMBLER WON’T START
1. Is the loading door completely closed?
2. Is the drying timer in an OFF position?
3. Has the PUSH TO START knob been depressed for 
three seconds?
4. Has a main fuse opened or is a main circuit breaker 
tripped?
TUMBLER WON’T HEAT
1. Is the Gas Shut-off Valve on the tumbler in the OFF 
position?
2. Is the tumbler in the cool down mode?
3. Is the lint screen clogged?
4. Is the airflow sufficient?
CLOTHES ARE NOT SATISFACTORILY DRY
1. Was enough heating time allocated for the load?
2. Is the lint screen clogged.
3. Is the exhaust duct to the outside clean and not 
blocked?
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected 
to ensure that the tumbler is properly grounded.
W002
WARNING