TROUBLESHOOTING THE 
TUMBLER
1. Exhaust airflow restriction.  Exhaust duct size is 
recommended to be larger than the exhaust opening.
2. Tumbler inlet air is essential for each unit.  Inlet air 
must be five to seven times the combined areas of the 
tumbler exhaust outlet.
3. All tumbler panels must be in place and on the 
machine for proper operation.
4. Gas Models Only:  Burner flame improperly 
adjusted.  Adjust the burner air sleeve.
5. Gas Models Only: Gas pressure must be 6 to 8 inches 
water column (1.49 to 1.74 kPa) for natural gas and 
11 inches water column (2.74 kPa) for propane 
(bottled gas).
6. Gas Models Only:  Make sure that the correct size of 
gas pipe is being used for the length of the gas circuit.
7. Gas Models Only:  Burner orifices must be the 
correct size.  Natural and L.P. gas do not use the same 
orifices.
8. The input voltage must be the same as that indicated 
on the serial plate.
9. The back draft damper must swing full open to 
prevent airflow restrictions.  (Less than full swing 
operation of the exhaust damper can cause the 
airflow switches to shut off gas, creating a longer 
drying time.)