Electrical Requirements
70269701
54
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electrical Requirements for Electric 
Models
NOTE: Minimum wire sizes are obtained from 
Canadian Electrical Code Table 2 for 75°C 
Conductors and are intended for use as a guideline 
only. Electrical connections should be made only by 
a qualified electrical contractor in accordance with 
all applicable local and national requirements.
NOTE: Electrical specifications below are subject 
to change without notice. Always refer to product 
serial plate for most current specifications of 
product being installed.
NOTE: Use copper conductors only.
NOTE: Connect to individual branch circuit.
NOTE: 3 Phase Only – Each tumbler must be 
connected to its own individual branch circuit 
breaker, not fuses, to avoid the possibility of “single 
phasing” and causing premature failure of the 
motor(s).
For 9 kW 25 Pound Electric Models:
For 12 kW 25 Pound Electric Models: 
Table 11 
Serial Plate 
Voltage
Terminal Block
Connections 
Required
Current 
(Amps)
Recommended 
Fuse or 
Breaker Rating 
(Amps)
Breaker 
Poles
Recommended 
Minimum
Conductor Size
[AWG (mm
2
)]
400V/50Hz/3ph
L1, L2, L3, 
and ground
16
20*
3
12 (3.31)
Serial Plate 
Voltage
Terminal Block
Connections 
Required
Current 
(Amps)
Recommended 
Fuse or 
Breaker Rating 
(Amps)
Breaker 
Poles
Recommended 
Minimum
Conductor Size
[AWG (mm
2
)]
208V/60Hz/1ph
L1, L2, Neutral, 
and ground
64
80
2
4 (21.2)
240V/60Hz/1ph
L1, L2, Neutral, 
and ground
57
80
2
4 (21.2)
200V/50Hz/1ph
L1, Neutral, 
and ground
63
80
1
4 (21.2)
230-240V/50Hz/
1ph
L1, Neutral, 
and ground
58
80
1
4 (21.2)
200-208V/60Hz/
3ph
L1, L2, L3, 
and ground
37
50*
3
6 (13.3)
200V/50Hz/3ph
L1, L2, L3, 
and ground
36
50*
3
6 (13.3)
230-240V/50Hz/
3ph
L1, L2, L3, 
and ground
33
50*
3
6 (13.3)
240V/60Hz/3ph
L1, L2, L3, 
and ground
33
50*
3
6 (13.3)
380V/50Hz/3ph
L1, L2, L3, 
and ground
20
25*
3
10 (5.26)
400-415V/50Hz/
3ph
L1, L2, L3, 
and ground
18
25*
3
10 (5.26)
460-480V/60Hz/
3ph
L1, L2, L3, 
and ground
16
25*
3
10 (5.26)
*
3 Phase machines should not have fuses, breakers only.