Installation
21
800937
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Grounding and Wiring Instructions
The dryer must be connected to a grounded 
metal, permanent wiring system; or an 
equipment-grounding conductor must be run 
with the circuit conductors and connected to the 
equipment-grounding terminal or lead on the 
dryer.
The dryer has its own terminal block that must be 
connected to a separate branch, 60 Hertz, single 
phase circuit, AC (alternating current) circuit, 
fused at 30 Amperes (the circuit must be fused 
on both sides of the line). ELECTRICAL 
SERVICE FOR THE DRYER SHOULD 
BE OF MAXIMUM RATED VOLTAGE 
LISTED ON THE NAMEPLATE. DO NOT 
CONNECT DRYER TO 110, 115, OR 
120 VOLT CIRCUIT.
 Heating elements are 
available for field installation in dryers which are 
to be connected to electrical service of different 
voltage than that listed on nameplate, such as 
208 Volt.
If branch circuit to dryer is 15 ft. (4.50 m) or less 
in length, use U.L. (Underwriters Laboratories) 
listed No. 10 A.W.G. wire (copper wire only), or 
as required by local codes. If over 15 ft. (4.50 m), 
use U.L. listed No. 8 A.W.G. wire (copper wire 
only), or as required by local codes. Allow 
sufficient slack in wiring so dryer can be moved 
from its normal location when necessary. 
The power cord (pigtail) connection between 
wall receptacle and dryer terminal block IS NOT 
supplied with dryer. Type of pigtail and gauge 
of wire must conform to local codes and with 
instructions mentioned on the following pages.
The method of wiring the dryer is optional and subject 
to local code requirements. Refer to Figure 26.