Installation
37
510969
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Make-Up Air Requirements
It is important that the laundry room has adequate 
make-up air for the dryer(s). A dryer exhausts 220 cfm 
(measured at back of the dryer) and sufficient make-up 
air must be supplied to replace the air exhausted by the 
dryer.
Make-Up Air Dos and Don’ts
Do
Supply adequate air for ventilating air, drying air 
and gas dryer combustion air. 
NOTE: Each-dryer pocket must have 40 square 
inches (260 cm
2
) of unobstructed flow of make-up 
air for proper operation.
Energy efficient buildings with low air 
infiltration rates should be equipped with an air 
exchanger that can accommodate on demand 
make-up air needs in the laundry room. These 
devices can be obtained through your building 
contractor or building material suppliers.
Don’t
Draw make-up air from a room containing a gas 
fired water heater.
Draw make-up air from a room containing a dry 
cleaner or a hair salon.
Exhaust Direction
The dryer can be exhausted to the outdoors through the 
back, left, right or bottom of the dryer. EXCEPTION: 
Gas dryers cannot be vented out the left side 
because of the burner housing.
Dryer is shipped from factory ready for rear exhaust; 
no kits required
.
Exhausting the dryer through sides or bottom can be 
accomplished by installing a DK1 Sales Accessory 
(Directional Exhaust Kit 528P3) available as optional 
equipment at extra cost.
Figure 27 
D361I
D361I
528P3 DIRECTIONAL EXHAUST KIT