Gas Requirements . . .
(Gas Dryers)
NOTE: The gas service to a gas dryer must conform 
with the local codes and ordinances, or in the absence 
of local codes and ordinances, with the latest edition of 
the National Fuel Gas Code ANSI Z223.1/NFPA 54 or 
the CAN/CGA-B149, National Gas Installation Code.
Natural Gas, 37.3 MJ/m
3
 (1,000 Btu/ft
3
), service must 
be supplied at 6.5 ± 1.5 inch water column pressure.
For proper operation at altitudes above 610 m (2,000 feet) 
the natural gas valve spud orifice size must be reduced to 
ensure complete combustion. See table at right.
L.P. (Propane) Gas, 93.1 MJ/m
3
 (2,500 Btu/ft
3
), service 
must be supplied at 10 ± 1.5 inch water column pressure.
NOTE: DO NOT connect the dryer to L.P. (Propane) 
Gas Service without converting the gas valve. A 458P3 
L.P. (Propane) Gas Conversion Kit must be installed 
by the Manufacturer’s Authorized Dealers, 
Distributors, or local service personnel.
NOTE: The dryer and its individual shut-off valve 
must be disconnected from the gas supply piping 
system during any pressure testing of that system at 
test pressures in excess of 3.45 kPa (1/2 psi). 
The dryer must be isolated from the gas supply piping 
system by closing its individual manual shut-off valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 
3.45 kPa (1/2 psi)
NOTE:  When connecting to a gas line, an equipment 
shutoff valve must be installed within 1.8 m (6') of the 
dryer. An 1/8" N.P.T. pipe plug must be installed as 
shown. See illustration.
Altitude
Orifice Size
Part
Number
m
ft
#
mm
Inches
610
2000
41
2.44
0.0960
503776
915
3000
42
2.37
0.0935
503777
1680
5500
43
2.26
0.0890
503778
2135
7000
44
2.18
0.0860
58719
2745
9000
45
2.08
0.0820
503779
3200
10500
46
2.06
0.0810
503780
To reduce the risk of gas leaks, fire or 
explosion:
• The dryer must be connected to the type of 
gas as shown on nameplate located in the 
door recess.
• Use a new flexible stainless steel 
connector.
• Use pipe joint compound insoluble in LP 
(propane) Gas, or Teflon tape, on all pipe 
threads.
• Purge air and sediment from gas supply 
line before connecting it to the dryer. 
Before tightening the connection, purge 
remaining air from gas line to dryer until 
odor of gas is detected. This step is 
required to prevent gas valve 
contamination.
• Do not use an open flame to check for gas 
leaks. Use a non-corrosive leak detection 
fluid.
W114R1
WARNING
D233IE2G
3/8" NPT
GAS CONNECTION
1/8" NPT
PIPE PLUG
(For checking
inlet gas pressure)
NEW 
STAINLESS
STEEL
FLEXIBLE
CONNECTOR
 USE ONLY 
IF ALLOWED 
BY LOCAL
CODES 
(Use
Design A.G.A.
Certified
Connector)
EQUIPMENT
SHUT-OFF
VALVE
Installed within 
1.8 m (6') of dryer
                 BLACK IRON PIPE
Shorter than 6.1 m (20') - use 3/8" pipe