Alliance Laundry Systems 504523R3 User Manual

Page of 82
20
504523
Location Requirements . . .
Select a location with a solid floor.
No other fuel burning appliance should be installed in the 
same closet with the dryer.
The dryer must not be installed or stored in an area where 
it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the dryer with 
a 1/4" driver. All four legs must rest firmly on the floor so 
the weight of the dryer is evenly distributed. The dryer 
must not rock.
The dryer needs sufficient clearance and an adequate air 
supply for proper operation and ventilation, and for easier 
installation and servicing. (Minimum clearances are 
shown below.)
CLOSET
DOOR
D337IE3A
FRONT VIEW
(w/o Closet Door)
SIDE VIEW
A
A
C
A
D
E
B
CENTERED
AIR 
OPENINGS (G)
(2 Openings 
Minimum)
FRONT VIEW
(Closet Door)
F
F
OUTER
WALL OF
ENCLOSURE
**42"
** NOTE: For new installations, locate top of wall vent 106 cm (42 inches) above floor to make venting 
easier to connect.
AREA
DESCRIPTION
FREE STANDING / 
ALCOVE INSTALLATION
(See Illustration)
CLOSET  INSTALLATION
(See Illustration)
A
Dryer sides and rear clearance
0 cm (0")
0 cm (0")
B
Dryer top clearance
30.5 cm (12")
30.5 cm (12")
C
Dryer front clearance
Not Applicable
5.1 cm (2")
D
Exhaust duct clearance to 
combustible material
5.1 cm (2")
5.1 cm (2")
E
Weather hood to ground 
clearance
30.5 cm (12")
30.5 cm (12")
F
Distance from floor or ceiling 
to hole edge
Not Applicable
7.6 cm (3")
G*
Area of centered air openings 
in closet door
Not Applicable
260 sq. cm/open  (40 sq. in.)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)