Installation
70304601
18
Before Placing Tumbler into Service
1. Remove or open all panels and check accessible 
bolts, nuts, screws, terminals and fittings for tightness.
2. Replace all panels and guards.
3. Remove and discard wire tie from the airflow 
switch so it can swing freely. Refer to Figure 4.
IMPORTANT: Airflow switch operation may be 
affected by:
• Clogged lint screen.
• Failure to remove wire tie from rear of 
machine. Refer to Figure 4.
• Lack of make-up air. Refer to Exhaust 
Requirements section.
• Obstruction in the exhaust duct. Refer to 
Exhaust Requirements section.
4. Turn on electrical supply to tumbler.
5. Open the supply valve for gas or steam heated tumblers.
6. After performing the previous checks, start the 
tumbler by pressing START. (Refer to the 
Operating Manual for detailed instructions.) 
Release the start button and open the loading 
door. The cylinder should stop rotating within 
seven seconds after the door is opened a 
maximum of 2 inches (51 mm). If it does not, 
adjust the loading door switch. Refer to 
Adjustments section.
7. Gas tumblers: Start the tumbler and check the 
burner flame. Adjust the air inlet shutter as 
required. Refer to Adjustments section.
IMPORTANT: The electronic ignition system will 
attempt to light the gas by sparking for the “trial 
for ignition” period. Refer to Table 2
. If gas does 
not ignite within this period, the ignition control 
will go into a safety lockout and the valve will no 
longer open until the control is reset. It may be 
necessary to retry several times to bleed air from 
the gas lines. To reset, open and close the loading 
door and restart tumbler.
If lockout condition persists, check that the manual 
gas shut-off valve is in the ON position and that the 
gas service is properly connected. If condition still 
persists, remove tumbler from service.
8. Load the cylinder with a full load of clean rags 
and run to remove oil or dirt from cylinder.
TMB2104N
1
Wire Tie
Figure 4
TMB2104N
1
Models Location
Prepurge 
Time 
(seconds)
Trial for 
Ignition 
(seconds)
To Reset 
Lockout 
Condition:
T30
CE and 
Australia
18
10
Press lighted 
reset button in 
rear contactor 
box
All others
 1-3
10
Open loading 
door
T45
 1-3
10
Open loading 
door
Table 2 
Do not operate tumbler if airflow switch is 
faulty. An explosive gas mixture could 
collect in tumbler if airflow switch does not 
operate properly.
W407
WARNING