Alliance Laundry Systems Drying Cabinet User Manual

Page of 53
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
70304601
20
Table 3 describes the different gases that are available 
in different CE countries, and how the machines need 
to be configured to operate with those gases. In the 
CE, there are Natural Gas configurations that do not 
allow for machine regulation, and L.P. Gas 
configurations that must be regulated. For L.P. Gas, 
third family B/P at 50 mbar, order regulated Natural 
Gas machines and convert according to Table 3.
Basic Configuration
1. Determine the necessary conversion operations to 
convert from the factory-supplied configuration 
to the desired configuration.
2. Perform the conversions required so the machine 
is properly configured for the desired country and 
gas (refer to Specific Conversion Procedures 
section):
How to Convert Gas Valve from Regulated to 
Unregulated
NOTE: Conversion from regulated to unregulated 
is only needed when regulated tumblers were 
ordered, but unregulated tumblers were needed, or 
if the gas supply type is changed at a later date.
How to Change Burner Orifice Size
How to Adjust Gas Valve Governor/Regulator
How to Change Regulator Spring, DE/AT 
Only
3. If applicable, peel off the appropriate country 
sticker (included with machine) and apply it to 
the serial plate over the existing country 
information.
4. If applicable, peel off the appropriate conversion 
sticker (included with machine) and apply it to 
the data plate over the “ADJUSTED FOR ______ 
GAS: ______” information.
5. Commission tumbler for use.
Figure 6 
T103K
1
Gas Shut-Off Valve (Ahead of pressure tap)
2
Pressure Tap
3
Gas Shut-Off Valve (Shown in closed position)
WARNING
When converting the tumbler to a 
different gas or pressure, first verify that 
the supply inlet pressure is equipped with 
a pressure regulator (located ahead of the 
tumbler) that will maintain the gas supply 
at the inlet pressure specified.
W430
SPECIFIED 
LOCAL INLET 
PRESSURE
3
2
1