Alliance Laundry Systems Drying Cabinet User Manual

Page of 53
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
23
70304601
How to Change Burner Orifice Size
1. Disconnect electrical power from tumbler. Close 
gas shut-off valve to tumbler. Refer to Figure 6.
2. For Johnson GM7000 gas valve:
Remove burner orifice(s) from the spud holder. 
Refer to Figure 7.
3. Install the new, correct burner orifices. Refer to 
Figure 8. Torque each to 9 – 10 Nm.
4. Commission tumbler for use.
NOTE: Blank burner orifices are available as Part 
No. M400995.
How to Adjust Gas Valve Governor/Regulator
1. Check gas burner orifice (manifold) pressure as 
follows. Refer to Figure 7.
2. Loosen screw plug inside pressure tap located on 
underside of valve.
3. Connect a “U”- tube manometer (or similar 
pressure gauge) to the tap.
4. Start tumbler and note pressure once flame is 
burning. Remove regulator cap and adjust 
regulator screw until the injector pressure per 
applicable table is achieved. Replace regulator 
cap and close needle valve (pressure tap).
5. Commission tumbler for use.
Figure 8 
TMB2015N
1
Size Stamped on Burner Orifice
1
BURNER
ORIFICE