Specific Conversion Procedures
How to Convert Gas Valve from Regulated to 
Unregulated
NOTE: Conversion from regulated to unregulated 
is only needed when regulated tumblers were 
ordered, but regulated tumblers were needed.
Johnson GM7000 gas valve:
1. Disconnect electrical power from tumbler. Close 
gas shut-off valve to tumbler. Refer to Figure 7.
2. Follow instructions in Conversion Kit, Part No. 
431485 (Johnson Part No. GM-70 CBP).
NOTE: This kit does not contain any burner 
orifices.
3. Change burner orifice size as required by the 
appropriate table according to How to Change 
Burner Orifice Size
.
4. Commission tumbler for use.
Figure 7 
TMB2135N
1
Gas Shut-Off Valve Assembly (closed position)
6
Required Burner Orifice Pressure
2
Gas Valve
7
Manometer
3
Burner Orifice
8
Hose - Connect Over Loosened Slotted 
4
Regulator Adjusting Housing and Gasket 
Pressure Tap Screw in Bottom of Gas Valve
(Regulated version shown)
9
Spud Holder
5
Gas Valve Bracket
10
Outlet Pressure Tap
TMB2135N