Electrical Requirements
70304601
40
Electrical Requirements for Gas and 
Steam Models
NOTE: Minimum wire sizes are obtained from 
Canadian Electrical Code for 75°C Conductors and 
are intended for use as a guideline only. Electrical 
connections should be made only by a qualified 
electrical contractor in accordance with all 
applicable local and national requirements.
For T30 Gas and Steam Models 
(For Total Machine):
NOTE: Electrical specifications below are subject 
to change without notice. Always refer to product 
serial plate for most current specifications of 
product being installed.
NOTE: Use copper conductors only.
NOTE: 3 Phase Only – Each tumbler must be 
connected to its own individual branch circuit 
breaker, not fuses, to avoid the possibility of “single 
phasing” and causing premature failure of the 
motor(s).
Table 9 
Serial Plate 
Voltage
Terminal Block
Connections 
Required
Current 
(Amps)
Recommended 
Fuse or 
Breaker Rating 
(Amps)
Breaker 
Poles
Recommended 
Minimum
Conductor Size
[AWG (mm
2
)]
120V/60 Hz/1ph
L1, Neutral, 
and ground
16.0
20
1
12 (3.31)
208-240V/60Hz/
1ph
L1, L2, Neutral, 
and ground
8.0
10
2
14 (2.08)
100V/60Hz/1ph
L1, Neutral, 
and ground
22.0
30
1
10 (5.26)
200-220V/60Hz/
1ph
L1, Neutral, 
and ground
11.6
15
1
14 (2.08)
100V/50Hz/1ph
L1, Neutral, 
and ground
24.2
35
1
8 (8.37)
200V/50Hz/1ph
L1, Neutral, 
and ground
15.0
20
1
12 (3.31)
230-240V/50Hz/
1ph
L1, Neutral, 
and ground
15.0
20
1
12 (3.31)
200-208V/60Hz/
3ph
L1, L2, L3, 
and ground
6.4
10*
3
14 (2.08)
240V/60Hz/3ph
L1, L2, L3, 
and ground
6.4
10*
3
14 (2.08)
200V/50Hz/3ph
L1, L2, L3, 
and ground
5.8
10*
3
14 (2.08)
230-240V/50Hz/
3ph
L1, L2, L3, 
and ground
7.0
10*
3
14 (2.08)
380V/50 or 60Hz/
3ph
L1, L2, L3, 
and ground
3.0
10*
3
14 (2.08)
400-415V/50Hz/
3ph
L1, L2, L3, 
and ground
3.2
10*
3
14 (2.08)
460-480V/60Hz/
3ph
L1, L2, L3,
and ground
3.3
10*
3
14 (2.08)
*
3 Phase machines should not have fuses, breakers only.