Steam Requirements
70304601
44
Installing Steam Trap and Making 
Condensate Return Connections
The steam trap must be installed and the coil outlet 
connections must be connected to the condensate 
return lines. The following steps outline the procedure 
for installing the steam trap and connecting the 
condensate return lines. Refer to Figure 14 for typical 
installations.
1. Use flexible lines between steam inlet solenoid 
and steam coils, as well as outlet between steam 
coil and traps.
2. If necessary, install a strainer at the end of each 
flexible hose.
3. Install a steam trap to each strainer.
IMPORTANT: Steam trap must be installed a 
minimum of 18 inches (457 mm) below the steam 
coil outlet connections.
4. Install a shut-off valve to each steam trap.
5. Connect to the condensate return lines.
6. For steam solenoid valve wiring connections, 
refer to Wiring Diagram supplied with tumbler.
WARNING
The flexible steam hoses connecting the 
coil outlet connections and steam traps 
must have a minimum of 125 psig 
(pounds per square inch gauge) (8.79 kg/
sq. cm.) working pressure. A shut-off 
valve must be installed downstream from 
each steam trap so the condensate return 
line can be isolated in event a steam trap 
requires maintenance.
Each steam trap must be supported so 
minimum load is exerted on the coil outlet 
connection.
W066