Whirlpool WED4890X Leaflet

Page of 1
29" Electric Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
WED4750X, WED4800X, WED4900X, 
WED4850X, WED4890X
Electrical
This dryer requires a 3 or 4 wire, single 
phase, 120/240 volt, 60 Hz., AC only electrical 
supply (or 3 or 4 wire, 120/208 volt electrical supply, 
if specified on the serial/rating plate) on a separate 
30-amp circuit, fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended. Connect 
to an individual branch circuit. Do not have a fuse in the 
neutral or grounding circuit.
Water
 
(Steam models only)
The dryer must be  
connected to the cold water faucet using new inlet 
hoses. Do not use old hoses. Do not overtighten.  
Damage to the coupling can result.
Exhaust venting
Exhaust your dryer to the outside. 
4" (102 mm) diameter vent is required. Rigid or flexible 
metal exhaust vent must be used. Do not use plastic  
or metal foil vet. Exhaust hood must be at least  
12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
Hood styles: A & B are recommended.
   
4"
(102 mm)
2½"
(64 mm)
     
4"
(102 mm)
      
4"
(102 mm)
B
A
A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 
C
Dryer dimensions
Select the route that will provide the straightest and most direct path outdoors.  
 
Plan the installation to use the fewest number of elbows and turns.  
 
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve 
Dimensions are for planning purposes only. For complete details, see Installation 
our products, we reserve the right to change materials and specifications without notice. 
Instructions packed with product. Specifications subject to change without notice.
Ref. W10096987 
02/2011
For closet installation, with a door, the minimum ventilation openings in the top  
and bottom of the door are required. Louvered doors with equivalent air ventilation  
openings are acceptable.
Do not use vent runs longer than specified in vent length chart.  
 
Determine the number of elbows you will need.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for 
the exhaust vent with elbow. See “Venting Requirements.”
Vent system chart
Number of 
90° elbows
Type  
of vent
Box/louvered
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal 54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The Vent system chart provides venting requirements 
that will help achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90° 
turn inside the dryer. To determine maximum exhaust 
length, add a 90° turn to the total number of elbows 
when referemcing the chart.
Minimum Required Spacing
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
 
A
B
C
    18"*
(457 mm)
  1"
(25 mm)
29"
(737 mm)
        1"
   (25 mm)
        1"*
    (25 mm)
14" max.*
(356  mm)
   
27
¾"
(705 mm)
  48 in.
  
(310 cm )
2
*
2
       3"*
(76 mm)
       3"*
(76 mm)
  
24 in.
(155 cm )
*
2
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
Vent System Chart
(Long Vent Models Only)
Number of 
90° turns  
or elbows
Type  
of vent
Box/louvered, or  
Angled hoods
1
4
3
2
0
Rigid metal
120 ft. (36.6 m)
110 ft. (33.5 m)
100 ft. (30.5 m)
90 ft. (27.4 m)
80 ft. (24.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
5
70 ft. (21.3 m)
Rigid metal
64 ft. (20 m)