Whirlpool W10471647B - SP User Manual

Page of 32
12
Do not use an exhaust hood with a magnetic latch.
Plan Vent System
Choose your exhaust installation type
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer. Other 
installations are possible.
H
G
F
E
D
C
A
B
A. Dryer
B. Elbow
C. Wall
D. Exhaust hood
E. Clamps
F. Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
Optional exhaust installations
This dryer can be converted to exhaust out the right side, left side, or 
through the bottom. If you prefer, you may contact your local dealer 
to have the dryer converted.
WARNING
Fire Hazard
Cover unused exhaust holes with the following kit:
W10470674 (midnight grey)
Contact your local dealer.
Failure to follow these instructions can result in death, 
fire, electrical shock, or serious injury.
A
B
C
A. Standard rear offset exhaust installation
B. Left or right side exhaust installation
C. Bottom exhaust installation
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best 
 
for your installation. Two examples of close-clearance installations 
are shown. Refer to the manufacturer’s instructions.
                                
            A
                                    
B
A. Over-the-top installation (also available with one offset elbow)
B. Periscope installation
NOTE: The following kits for close-clearance alternate installations 
are available for purchase. Please see the “Assistance or Service” 
section to order.
Over-the-Top Installation: 
Part Number 4396028
Periscope Installation (For use with dryer vent to wall vent 
mismatch):
Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch
Part Number 4396011 - 18" (460 mm) to 29"(737 mm) mismatch
Part Number 4396014 - 29" (737 mm) to 50" (1270 mm) 
mismatch
Special provisions for mobile home installations
The exhaust vent must be securely fastened to a noncombustible 
portion of the mobile home structure and must not terminate 
beneath the mobile home. Terminate the exhaust vent outside.
Determine vent path
Select the route that will provide the straightest and most direct 
path outdoors.