Whirlpool W10471647B - SP User Manual

Page of 32
7
Recommended installation spacing for cabinet 
installation
NOTE: Some models are not recommended for cabinet installation.
For cabinet installation, with a door, minimum ventilation 
openings in the top of the cabinet are required.
A*
B*
C*
D**
E
F*
H
I
G
Steam 
(Electric or Gas)
Non-Steam 
(Electric or Gas)
A*
7" (178 mm)
7" (178 mm)
B*
7" (178 mm)
7" (178 mm)
C*
9" (229 mm)
9" (229 mm)
D**
5" (127 mm)
5" (127 mm)
E
32 
9
/
16
" (827mm)
31 
1
/
2
" (800 mm)
F*
1" (25 mm)
1" (25 mm)
G
1" (25 mm)
1" (25 mm)
H
27" (686 mm)
27" (686 mm)
I
1" (25 mm)
1" (25 mm)
*Required spacing
 **For side or bottom venting, 0" (0 mm) spacing is allowed.
Recommended installation spacing for recessed or 
closet installation, with stacked washer and dryer 
The dimensions shown are for the recommended spacing.
48 in.
2
 *
(310 cm
2
)
3"* (76 mm)
3"* (76 mm)
1"* (25 mm)
24 in.
2
 *
(155 cm
2
)
6"* (152 mm)
    76"
(1930 mm) 
     27"
(686 mm)
  A*
  1"
(25 mm)
   1"
(25 mm)
 
Steam 
(Electric or Gas)
Non-Steam 
(Electric or Gas)
A*
5 ½" (140 mm)
5" (127 mm)
*Required spacing
NOTE: Some models are not recommended for stacked recessed or 
closet installation.
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation 
must conform to the Manufactured Home Construction and Safety 
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for 
Mobile Home Construction and Safety, Title 24, HUD Part 280) or 
Standard CAN/CSA-Z240 MH.
Mobile home installations require:
All Dryers
Metal exhaust system hardware, which is available for purchase 
from your dealer.
Special provisions must be made in mobile homes to introduce 
outside air into the dryer. The opening (such as a nearby 
window) should be at least twice as large as the dryer exhaust 
opening.
For gas dryers
Mobile Home Installation Kit Part Number 346764. See “Tools 
and Parts” section for information on ordering.