Page of 1
27" Electric Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
WED5500X, WED5550X, 
WED5600X, WED5700X
Electrical
This dryer requires a 3 or 4 wire, single 
phase, 120/240 volt, 60 Hz., AC only electrical 
supply (or 3 or 4 wire, 120/208 volt electrical supply, 
if specified on the serial/rating plate) on a separate 
30-amp circuit, fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended. Connect 
to an individual branch circuit. Do not have a fuse in the 
neutral or grounding circuit.
Exhaust venting
Exhaust your dryer to the outside. 
4" (102 mm) diameter vent is required. Rigid or flexible 
metal exhaust vent must be used. Do not use plastic  
or metal foil vent. Exhaust hood must be at least  
12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
Exhaust hood styles
 
Vent System Chart:  
Dryer dimensions
Select the route that will provide the straightest and most 
direct path outdoors. Plan the installation to use the fewest 
number of elbows and turns. Use the fewest 90° turns 
possible. Do not use vent runs longer than specified in 
vent length chart. Determine the number of elbows you
will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve 
Dimensions are for planning purposes only. For complete details, see Installation 
our products, we reserve the right to change materials and specifications without notice. 
Instructions packed with product. Specifications subject to change without notice.
Ref. W10096988
04/2010
For closet installation, with a door, the minimum ventilation openings in the top 
and bottom of the door are required. Louvered doors with equivalent air ventilation 
openings are acceptable.
For cabinet installation, with a door, the minimum ventilation openings in the top are 
required.
NOTE: Side and bottom exhaust installations have a 90° 
turn inside the dryer. To determine maximum exhaust length, 
add one 90° turn to the chart.
     
4"
(102 mm)
      
4"
(102 mm)
B
A
   
4"
(102 mm)
2½"
(64 mm)
C
Recommended styles:
A. Louvered hood
B. Box hood
Acceptable styles:
C. Angled hood
Number 90º 
elbows
Type of vent
Box /louvered 
hoods
Angled 
hoods
0
Rigid metal
64 ft. (20 m)
58ft. (17.7 m)
1
Rigid metal
54 ft. (16.5 m) 
48 ft. (14.6 m)
2
Rigid metal
44 ft. (13.4 m)
38 ft. (11.6 m)
3
Rigid metal
35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)
Minimum required spacing
43"
(1092 mm)
*29
1
/
2
"
(749 mm)
27"
(687 mm)
A
23¾"
(603 mm)
43"
(1092 mm)
*29
1
/
2
"
(749 mm)
27"
(687 mm)
B
13¾"
(349 mm)
A. Large opening side-swing door
B. Wide opening hamper door
 
A
B
C
    18"*
(457 mm)
  1"
(25 mm)
27"
(686 mm)
        1"
   (25 mm)
        1"*
    (25 mm)
14" max.*
(356  mm)
 
  29 ¼"
(743 mm)
   
5 ½"*
 (140 mm)
  48 in.
  
(310 cm )
2
*
2
  
24 in.
(155 cm )
*
2
       
3"*
(76 mm)
       
3"*
(76 mm)
A. Recessed area
C. Closet door with vents
*Additional spacing recommended
* Most intallations require a minimum 5 
1/2
" (140 mm) clearance behind the dryer for 
the exhaust vent with elbow. See "Venting Requirements" in the Use and Care Guide
.