ELECTRICAL REQUIREMENTS
VENTING REQUIREMENTS
E
xhaust venting: Exhaust your dryer to the outside. 4" (102 mm) 
diameter vent is required. Rigid or flexible metal exhaust vent 
must be used. Do not use plastic or metal foil vet. Exhaust hood 
must be at least 12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
NOTE: Bottom exhaust installations have a 90º turn inside the 
dryer. To determine maximum exhaust length, add one 90º turn  
to the chart.
Determine vent length and elbows needed for best 
drying performance:
 
Use following Vent System Chart to determine type of vent 
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified  
in Vent System Chart. Exhaust systems longer than those 
specified will:
 
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times  
and increased energy usage.
Louvered Hood
Angled Hood
Box Hood
Exhaust hoods:
Recommended Styles:
Acceptable Style:
The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.  
Damage to the coupling can result.
A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit  
are recommended. 
 
   
 
GAS SUPPLY REQUIREMENTS
Gas supply
This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When 
acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger 
tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed 
within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. 
 
WATER (STEAM MODELS ONLY) REQUIREMENTS
Determine vent path:
 
Select route that will provide straightest and most direct  
path outdoors.
 
Plan installation to use fewest number of elbows and 
turns.
 
When using elbows or making turns, allow as much 
room  
as possible.
 
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.
INSTALLATION REQUIREMENTS
W10423115A 
09/2011
Vent System Chart
Number of 
90° elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)