Whirlpool GEW9260PL1 User Manual

Page of 28
5
Location Requirements
You will need
A location that allows for proper exhaust installation. See 
“Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical 
outlet located within 2 ft (61 cm) of either side of the dryer. 
See “Electrical Requirements.”
A sturdy floor to support the total dryer weight of 200 lbs 
(90.7 kg). The combined weight of a companion appliance 
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire 
dryer. If slope is greater than 1" (2.5 cm), install Extended 
Dryer Feet Kit, Part Number 279810. Clothes may not tumble 
properly and automatic sensor cycles may not operate 
correctly if dryer is not level.
For a garage installation, you will need to place the dryer at 
least 18" (46 cm) above the floor. If using a pedestal, you will 
need to place the pedestal at least 6" (22.9 cm) above the 
floor.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes or 
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to 
open fully.
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door and 
floor moldings.
Companion appliance spacing should also be considered.
Dryer Dimensions
*Most installations require a minimum 5½" (14 cm) clearance   
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Minimum installation spacing for custom undercounter 
installation
The dimensions shown are for the minimum spacing allowed.
Custom undercounter installation - Dryer only
*Additional spacing recommended
Minimum installation spacing for recessed or closet 
installation, with or without a pedestal
The dimensions shown are for the minimum spacing allowed.
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
Closet installation - Dryer only
*Side or bottom venting - additional spacing recommended
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
A. Side view - closet or confined area
B. Closet door with vents
      38"
(96.52 cm)
 *31½"
(80 cm)
     27"
(68.6 cm)
     51½"
(130.81 cm)
    0"*
  (0 cm)
    0"*
(0 cm)
    0"*
(0 cm)
  38" min.
(96.52 cm)
     27"
(68.6 cm)
A
B
14" max.
(35.6 cm)
18" min.
(45.72 cm)
    1"
   0"*
(0 cm)
   31½"
(80 cm)
48 in.
(310 cm
2
)
24 in.
2
(155 cm
2
)
      3"
(7.6 cm)
      3"
(7.6 cm)
    (2.5 cm)