Whirlpool W10097001A-SP User Manual

Page of 20
11
1.
 
Prepare to connect neutral 
     ground wire and neutral wire
A
E
B
Remove center, silver-colored terminal block screw (B).  
Remove neutral ground wire (E) from external ground  
conductor screw (A).
B
C
E
Connect neutral ground wire 
and neutral wire
2. 
Connect neutral ground wire (E) and neutral wire (white or 
center wire) (C) of power supply cord or cable under center, 
silver-colored terminal block screw (B). Tighten screw.
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal 
block screws (hooks facing right). Tighten screws. 
A
G
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external 
ground conductor screw (A) to an adequate ground. Finally, 
reinsert tab of terminal block cover into slot of dryer rear 
panel. Secure cover with hold-down screw. 
now, go to 
Venting Requirements. 
optional 3-wire Connection
You must verify with a qualified  electrician that this 
grounding method is acceptable before connecting.
Connect remaining wires
7.
Place hooked ends of remaining direct wire cable wires  
under outer terminal block screws (hooks facing right).  
Squeeze hooked ends together and tighten screws. Finally, 
reinsert tab of terminal block cover into slot of dryer rear  
panel. Secure cover with hold-down screw. 
now, go to  
Venting Requirements.
C
B
Place hooked end of neutral wire (white or center) (C) of direct 
wire cable under center terminal block screw (B). Squeeze 
hooked end together. Tighten screw.
6.
 
Connect neutral wire