Whirlpool W10097001A-SP User Manual

Page of 20
3
Adjustable wrench that 
opens to 1" (25 mm)  or 
hex-head socket wrench 
Vent clamps
1/4" nut driver 
(recommended)
Utility knife 
 Level
Tape measure
Pliers
Caulking gun and 
compound (for installing 
new exhaust vent)
Parts package is located in dryer drum. Check that all parts  
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting, 
and read “Electrical Requirements” and “Venting Requirements” 
before purchasing parts.
Mobile home installations require metal exhaust system 
hardware, available for purchase from the dealer from whom you 
purchased your dryer. For further information, please reference 
the “Assistance or Service” section of the Dryer  
User Instructions.
Parts supplied (all models): 
Leveling legs (4)
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with 
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt 
 
minimum. The cord should be type SRD or SRDT and be  
at least 4 ft. (1.22 m) long. The wires that connect to the  
dryer must end in ring terminals or spade terminals with 
upturned ends.
A UL listed strain relief.
 
location Requirements
You will need:
A location allowing for proper exhaust installation.  
 
See “Venting Requirements.”
A separate 30 amp circuit.
 
If you are using power supply cord, a grounded electrical 
 
outlet located within 2 ft. (610 mm) of either side of dryer.  
See “Electrical Requirements.”
A sturdy floor to support the total weight (dryer and load) 
 
of 200 lbs. (90.7 kg). The combined weight of a companion 
appliance should also be considered.
Level floor with maximum slope of 1" (25 mm) under entire 
 
dryer. (If slope is greater than 1" [25 mm], install Extended  
Dryer Feet Kit, Part Number 279810.) If not level, clothes  
may not tumble properly and automatic sensor cycles may  
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
Installation clearances:
The location must be large enough to allow the dryer door to 
open fully.