Plan pipe fitting connection
 2.
A combination of pipe fittings must be used to connect dryer 
to existing gas line. A recommended connection is shown. 
Your connection may be different, according to supply line 
type, size, and location.
A. 3/8" flexible gas connector
B. 3/8" dryer pipe 
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare adapter fitting
Open shut-off valve in supply line; valve is open when handle 
is parallel to gas pipe. Then, test all connections by brushing 
on an approved noncorrosive leak-detection solution. 
Bubbles will show a leak. Correct any leaks found.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
Connect Vent
Connect vent to exhaust outlet
1.
Move dryer to final location
2.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet  
in dryer. If connecting to existing vent, make sure vent is 
clean. Dryer vent must fit over dryer exhaust outlet and inside 
exhaust hood. Check that vent is secured to exhaust hood 
with a 4" (102 mm) clamp.
Move dryer to final location. Avoid crushing or kinking vent. 
After dryer is in place, remove corner posts and cardboard 
from under the dryer.
Connect vent to exhaust hood
2.
Vent must fit over the exhaust hood. Secure vent to exhaust 
hood with 4" (102 mm) clamp. Run vent to dryer location 
using straightest path possible. Avoid 90° turns. Use clamps 
to seal all joints. Do not use duct tape, screws, or other 
fastening devices that extend into interior of vent to secure 
vent, because they can catch lint.
A
B
Connect gas supply to dryer
 1.
Remove red cap from gas pipe. Using a wrench to tighten, 
connect gas supply to dryer. Use pipe-joint compound  
on threads of all non-flared male fittings. If flexible metal  
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint 
compound resistant to action of LP gas. Do not use  
TEFLON
®†
 tape.