GAS DRYER POWER 
HOOkUP
Gas Supply Requirements
Gas type
Natural gas:
This dryer is equipped for use with Natural Gas. It is design-
certified by CSA International for LP (propane or butane) gases 
with appropriate conversion.
Your dryer must have the correct burner for the type of gas  
 
in your home. Burner information is located on the rating  
plate in the door well of your dryer. If this information does  
not agree with the type of gas available, please reference 
the “Assistance or Service” section of the “Dryer User 
Instructions.” 
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the dryer from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier.
IMPORTANT: The gas installation must conform with local codes, 
or in the absence of local codes, with the National Fuel Gas 
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and 
Propane Installation Code, CSA B149.1.
Gas supply line
1/2" NPT pipe is recommended.
 
3/8" approved tubing is acceptable for lengths under  
 
20 ft. (6.1 m) if local codes and gas supplier permit.
Must include 1/8" NPT minimum plugged tapping accessible 
 
for test gauge connection, immediately upstream of the gas 
connection to the dryer (see illustration).
Must include a shut-off valve:
 
In the U.S.A.:
An individual manual shut-off valve must be installed within   
six (6) feet (1.8 m) of the dryer in accordance with the 
National Fuel Gas Code, ANSI Z223.1. 
In Canada:
An individual manual shut-off valve must be installed in 
accordance with the B149.1, Natural Gas and Propane 
Installation Code. It is recommended that an individual 
manual shut-off valve be installed within six (6) feet (1.8 m)  
of the dryer.
The shut-off valve location should be easy to reach for opening 
and closing.
A
B
E
D
C
A. 3/8" flexible gas connector
B. 3/8" pipe to flare adapter fitting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shut-off valve
Gas supply connection requirements
There are many methods by which your gas dryer can be 
connected to the gas supply. Listed here are some guidelines  
for two different methods of connection.
This dryer must be connected to the gas supply line with a 
listed flexible gas connector that complies with the standard for 
connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
Screw in leveling legs
2. 
Examine leveling legs and find diamond marking. Screw legs 
into leg holes by hand. Use a wrench to finish turning legs 
until diamond marking is no longer visible.
Now stand the dryer on its feet. Slide the dryer until it is 
close to its final location. Leave enough room to connect the 
exhaust vent.
For mobile home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home Installation 
Hold-down Kit. For ordering information please reference the 
“Dryer User Instructions.”
diamond