Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this 
dryer. This dryer has been tested for spacing of 0" (0 mm) 
clearance on the sides and rear. Recommended spacing should 
be considered for the following reasons:
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door, and 
floor moldings.
Additional spacing should be considered on all sides of the 
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
Companion appliance spacing should also be considered. 
Additional spacing is required if you exhaust out the rear of 
the dryer to either the right or left side. 
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The 
installation must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-
Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for 
purchase from your dealer.
Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.
Electrical Requirements - U.S.A. Only
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in 
conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances. 
The National Electrical Code requires a 4-wire power supply 
connection for homes built after 1996, dryer circuits involved 
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt 
electrical supply, if specified on the serial/rating plate) on a 
separate 30-amp circuit, fused on both sides of the line. A 
time-delay fuse or circuit breaker is recommended. Connect 
to an individual branch circuit. Do not have a fuse in the 
neutral or grounding circuit. 
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
This dryer is manufactured ready to install with a 3-wire 
electrical supply connection. The neutral ground conductor is 
permanently connected to the neutral conductor (white wire) 
within the dryer. If the dryer is installed with a 4-wire electrical 
supply connection, the neutral ground conductor must be 
removed from the external ground connector (green screw), 
and secured under the neutral terminal (center or white wire) 
of the terminal block. When the neutral ground conductor is 
secured under the neutral terminal (center or white wire) of 
the terminal block, the dryer cabinet is isolated from the 
neutral conductor.
If local codes do not permit the connection of a neutral 
ground wire to the neutral wire, see “Optional 3-wire 
connection” in “Electrical Connection - U.S.A. Only” section. 
A 4-wire power supply connection must be used when the 
appliance is installed in a location where grounding through 
the neutral conductor is prohibited. Grounding through the 
neutral is prohibited for (1) new branch-circuit installations, 
(2) mobile homes, (3) recreational vehicles, and (4) areas 
where local codes prohibit grounding through the neutral 
conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with 
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt 
minimum. The cord should be type SRD or SRDT and be at 
least 4 ft (1.22 m) long. The wires that connect to the dryer 
must end in ring terminals or spade terminals with upturned 
ends.
A UL listed strain relief.
If your outlet looks like this:
4-wire receptacle (14-30R)
Then choose a 4-wire power supply cord with ring or spade 
terminals and UL listed strain relief. The 4-wire power supply 
cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper 
wires and match a 4-wire receptacle of NEMA Type 14-30R. The 
ground wire (ground conductor) may be either green or bare. The 
neutral conductor must be identified by a white cover.
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
A
B
C
    18"*
(457 mm)
   1" 
(25 mm)
       29"
(737 mm)
        1"
(25 mm)
        1"*
     (25 mm)
14" max.*
(356 mm)
 
   29¼"
(743 mm)
    5"
 (127 mm)
  48 in.   * 
(310 cm  )
2
2
  24 in.  *
(155 cm  )
2
2
       3"*
(76 mm)
       3"*
(76 mm)