1.
 
Prepare to connect neutral 
     ground wire and neutral wire
A
E
B
Remove center terminal block screw (B). Remove neutral ground 
wire (E) from external ground conductor screw (A).
E
B
C
Connect neutral ground wire 
and neutral wire
2. 
Connect neutral ground wire (E) and neutral wire (white or 
center wire) (C) of power supply cord or cable under center 
terminal block screw (B). Tighten screw.
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal 
block screws (hooks facing right). Tighten screws. 
A
G
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external 
ground conductor screw (A) to an adequate ground. Finally, 
reinsert tab of terminal block cover into slot of dryer rear 
panel. Secure cover with hold-down screw. Now, go to 
“Venting Requirements.” 
Optional 3-Wire Connection
IMPORTANT
: You must verify with a qualified  
electrician that this grounding method is acceptable  
before connecting.
Connect remaining wires
4.
Place hooked ends of remaining direct wire cable wires  
under outer terminal block screws (hooks facing right).  
Squeeze hooked ends together and tighten screws. Finally, 
reinsert tab of terminal block cover into slot of dryer rear  
panel. Secure cover with hold-down screw. Now, go to  
“Venting Requirements.”
B
C
Place hooked end of neutral wire (white or  
center) (C) of direct wire cable under center  
terminal block screw (B). Squeeze hooked  
end together. Tighten screw.
3.
 