Location Requirements 
You will need
A location that allows for proper exhaust installation. See 
“Venting Requirements.”
A separate 30-amp circuit.
If you are using a power supply cord, a grounded electrical 
outlet located within 2 ft (610 mm) of either side of the dryer. 
 
See “Electrical Requirements.”
A sturdy floor to support the total dryer weight of 200 lbs 
 
(90.7 kg). The combined weight of a companion appliance 
should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire 
dryer. If slope is greater than 1" (25 mm), install Extended Dryer 
Feet Kit, Part Number 279810. Clothes may not tumble properly 
and automatic sensor cycles may not operate correctly if dryer is 
not level.
For a garage installation, you will need to place the dryer at least 
18" (460 mm) above the floor. If using a pedestal, you will need 
18" (460 mm) to the bottom of the dryer.
Steam models only: Cold water faucets located within 4 ft 
 
(1.2 m) of the dryer, and water pressure of 20-100 psi 
 
(137.9-689.6 kPa). You may use the cold water supply from 
 
your washer using the “Y” connector provided.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic sensor cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will 
 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to 
 
open fully.
Dryer Dimensions
A
B
C
D
Steam 
(Electric or Gas)
Non-Steam
(Electric or Gas)
A
38" (9652 mm)
38" (9652 mm)
B
32 
9
/
16
" (686 mm)
31 
1
/
2
" (800 mm)
C
27" (686 mm)
27" (686 mm)
D
52 
9
/
16
" (1335 mm)
51 
1
/
2
" (1308 mm)
NOTE: Most installations require a minimum 5" (127 mm) clearance 
behind the dryer for the exhaust vent with elbow. 
 
See “Venting Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. 
This dryer has been tested for spacing of 0" (0 mm) clearance on the 
sides and rear. Recommended spacing should be considered for the 
following reasons:
Additional spacing should be considered for ease of installation 
and servicing.
Additional clearances might be required for wall, door, and floor 
moldings.
Additional spacing should be considered on all sides of the dryer 
to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings 
in the top and bottom of the door are required. Louvered doors 
with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.