Electrical Connection - U.S.A. Only
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord. 
Use a UL listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
 
1. Disconnect Power.
2. Remove the hold-down screw and terminal block cover.
A. Neutral ground wire 
B. External ground conductor 
screw
C. Center silver-colored terminal 
block screw
D. Terminal block cover and 
 
hold-down screw
A
B
C
D
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws 
from a 
3
/
4
" (19 mm) UL 
listed strain relief (UL 
marking on strain 
relief). Put the tabs of 
the two clamp 
sections into the hole 
below the terminal 
block opening so that 
one tab is pointing up 
and the other is 
pointing down, and 
hold in place. Tighten 
strain relief screws 
enough to hold the two clamp sections together.   
A. Strain relief tab pointing up
B. Hole below terminal block 
opening
C. Clamp section
D. Strain relief tab pointing down
Put power supply cord 
through the strain relief. 
Be sure that the wire 
insulation on the power 
supply cord is inside 
the strain relief. The 
strain relief should have 
a tight fit with the dryer 
cabinet and be in a 
horizontal position. 
 
Do not further tighten 
strain relief screws at 
this point. 
Style 2: Direct wire strain relief
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
Unscrew the removable conduit connector and any screws 
from a 
3
/
4
" (19 mm) UL listed strain relief (UL marking on 
strain relief). Put the threaded section of the strain relief 
through the hole below the terminal block opening. 
Reaching inside the terminal block opening, screw the 
removable conduit connector onto the strain relief threads.   
A
B
C
A. Removable conduit connector
B. Hole below terminal block opening
C. Strain relief threads
A
B
C
D