Electrical Connection
Power Supply Cord
WARNING
Fire Hazard
use a new ul listed 30 amp power supply cord. 
use a ul listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
Direct Wire
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
Electrical Connection options
If your home has:
And you will be 
connecting to:
Go to 
Section:
4-wire receptacle (NEMA 
Type 14-30R) 
A UL listed, 120/240-
volt minimum, 30-
amp, dryer power 
supply cord*
4-wire 
connection: 
Power 
supply cord
3-wire receptacle (NEMA 
type 10-30R) 
A UL listed, 120/240-
volt minimum, 30-
amp, dryer power 
supply cord*
3-wire 
connection: 
Power 
supply cord
4-wire direct 
A fused disconnect 
or circuit breaker 
box*
4-wire 
connection: 
Direct Wire
3-wire direct 
A fused disconnect 
or circuit breaker 
box*
3-wire 
connection: 
Direct Wire
*If local codes do not permit the connection of a cabinet-ground  
 conductor to the neutral wire, go to “Optional 3-wire connection”  
 section.
1.  Disconnect power.
2.  Remove the hold-down screw (D) and terminal block  
cover (A).
A
B
C
D
E
F
A. Terminal block cover 
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Hold-down screw 
E. Neutral ground wire
F. Hole below terminal block cover