Duet  Steam and Non-Steam Electronic Gas Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
WGD9600T, WGD9450W,
WGD9550W, WGD9750W
Gas supply
This dryer is equipped for use with Natural 
gas. Dryer can be converted to L.P. gas. When rigid 
pipe is used it should be 1/2" IPS. When acceptable  
to the gas supplier and local codes, 3/8" approved  
tubing may be used for lengths under 20 ft (6.1 m).  
For lengths over 20 ft (6.1 m), larger tubing should be 
used. Pipe-joint compounds resistant to the action of 
L.P. gas must be used. An individual manual shutoff 
valve must be installed within 6 ft (1.8 m) of the dryer 
in accordance with the National Fuel Gas Code ANSI 
Z223.1. 
 
Electrical
A 120-volt, 60 Hz, AC-only, 15 or 20 amp 
fused electrical supply is required. A time-delay fuse or 
circuit breaker and a separate circuit are recommended. 
 
Water
 
(Steam models only)
The dryer must be  
connected to the cold water faucet using new inlet 
hoses. Do not use old hoses. Do not overtighten.  
Damage to the coupling can result.
Exhaust venting
Exhaust your dryer to the outside. 
4" (102 mm) diameter vent is required. Rigid or flexible 
metal exhaust vent must be used. Do not use plastic  
or metal foil vet. Exhaust hood must be at least  
12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
Hood styles: A & B are recommended.
The vent system chart provides venting requirments 
that will help to achieve the best drying performance.
Vent system chart:
  
NOTE: Side and bottom exhaust installations have  
a 90° turn inside the dryer. To determine maximum  
exhaust length, add one 90° turn to the chart.
   
4"
(102 mm)
2½"
(64 mm)
     
4"
(102 mm)
      
4"
(102 mm)
B
A
A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 
C
Number of 
90  turns 
or elbows
Type of
vent
Box or 
Louvered 
hoods
Angled
hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
54 ft (16.5 m) 
48 ft (14.6 m)
2
44 ft (13.4 m)
38 ft (11.6 m)
3
35 ft (10.7 m)
29 ft (8.8 m)
4
27 ft (8.2 m)
21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
 27"
(686 mm)
38"
(965 mm)
NON-STEAM - 51
1
/
2
"
(1308 mm)
STEAM - 52
9
/
16
"
(1335 mm)
NON-STEAM - 31
1
/
2
"
(800 mm)
*STEAM - 32
9
/
16
"
(827 mm)
 
 27"
(686 mm)
38"
(965 mm)
1"*
(25 mm)
1"*
(25 mm)
NON-STEAM - 5"** 
(127 mm)
STEAM - 5
1
/
2
"**
(140 mm)
NON-STEAM - 31
1
/
2
"
(800 mm)
STEAM - 32
9
/
16
"
(827 mm)
 27"
(686 mm)
 14" max.
(356 mm)
 18" max.
(457 mm)
1"
(25 mm)
1"
(25 mm)
76"
(1930 mm)
6"
(152 mm)
3"
(76 mm)
3"
(76 mm)
48 in.
*
(310 cm
2
)
24 in.
*
(155 cm
2
)
5"
(127 mm)
NON-STEAM - 31
1
/
2
"
(800 mm)
STEAM - 32
9
/
16
"
(827 mm)
 14"* max.
(356 mm)
9"*
(229 mm)
7"*
(178 mm)
7"*
(178 mm)
 18"* max.
(457 mm)
 27"
(686 mm)
1"*
(25 mm)
1"*
(25 mm)
14"
(356 mm)
3
7
/
16
"
(87 mm)
1"
(25 mm)
7
5
/
8
"
(194 mm)
3
3
/
8
"
(86 mm)
1"
(25 mm)
Custom undercounter installation-dryer only
† Most installations require a minimum  
5" (127 mm) clearance behind the dryer for 
the exhaust vent with elbow. See Installation 
Instructions, “Venting Requirements.”
Back View
Side View
Select the route that will provide the straightest and most direct path outdoors.  
Plan the installation to use the fewest number of elbows and turns.  
Use the fewest 90° turns possible. 
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve 
Dimensions are for planning purposes only. For complete details, see Installation 
our products, we reserve the right to change materials and specifications without notice. 
Instructions packed with product. Specifications subject to change without notice.
Ref. W10255469B
07/2009
For closet installation, with a door, the minimum ventilation openings in the top and bot-
tom of the door are required. Louvered doors with equivalent air  
ventilation openings are acceptable.
For cabinet installation, with a door, the minimum ventilation 
openings in the top are required.
 *Required spacing  **For side or bottom venting, 2" (51 mm) spacing is allowed.
Dryer dimensions