Whirlpool W10240583C-SP User Manual

Page of 20
16
Vent System Chart
number of 
90° turns  
or elbows
Type  
of vent
Box/louvered 
hoods
Angled  
hoods
0
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
1
Rigid metal 54 ft. (16.5 m)
48 ft. (14.6 m)
2
Rigid metal 44 ft. (13.4 m)
38 ft. (11.6 m)
3
Rigid metal 35 ft. (10.7 m)
29 ft. (8.8 m)
4
Rigid metal
27 ft. (8.2 m)
21 ft. (6.4 m)
The Vent System Chart provides venting requirements that will 
help achieve best drying performance.
noTE: Bottom exhaust installations have a 90º turn inside the 
dryer. To determine maximum exhaust length, add one 90º turn  
to the chart.
Determine vent path:
Select route that will provide straightest and most direct  
 
path outdoors.
Plan installation to use fewest number of elbows and turns.
 
When using elbows or making turns, allow as much room  
 
as possible.
Bend vent gradually to avoid kinking.
 
Use as few 90° turns as possible.
 
Determine vent length and elbows needed for best 
drying performance:
Use following Vent System Chart to determine type of vent 
 
material and hood combinations acceptable to use.
noTE: Do not use vent runs longer than those specified  
in Vent System Chart. Exhaust systems longer than those 
specified will:
Shorten life of dryer.
 
Reduce performance, resulting in longer drying times  
 
and increased energy usage.
INSTALL vENT SYSTEM
1. 
Install exhaust hood
12" min.
(305 mm)
12" min.
(305 mm)
Install exhaust hood and use caulking compound to seal 
exterior wall opening around exhaust hood.
2. 
Connect vent to exhaust hood
Vent must fit over the exhaust hood. Secure vent to exhaust 
hood with 4" (102 mm) clamp. Run vent to dryer location using 
straightest path possible. Avoid 90° turns. Use clamps to seal 
all joints. Do not use duct tape, screws, or other fastening 
devices that extend into interior of vent to secure vent, 
because they can catch lint.