Sony DXC-9100P User Manual

Page of 188
50
Remote Controlling the Camera from an External Pulse Signal
The image can be captured to the built-in frame memory as
a still image using a pulse signal input to the EXT CTRL
connector from a remote sensor and switch.
For details of the timing of the pulse input to the EXT CTRL
connector, see “Capturing the Image into Memory by Using the
Freeze Function” on page 33.
Connection to Enable Remote Control
Camera cable: CCXC-9DB (D-sub 9-pin)
˜
BNC
connectors), or CCMC-9DS (D-sub 9-pin)
˜
BNC, S-video
connectors)
or
RGB/SYNC
R input
G input
B input
Sync input
a)
Composite video (BNC) or
S-video input (4-pin)
b)
RGB monitor, multi-
scan monitor, multi-
scan printer
c)
, image
processor, etc.
Computer, image
processor, etc.
DC IN/VBS
CAMERA (4-pin or 12-pin)
Power cord
CCDC-5/10/25/50A/100A cable or
CCMC-12P02/05/20/25 cable
DXC-9100P
RGB/SYNC
Camera cable CCXC-9DD (D-sub 9-pin
˜
D-sub 9-pin)
For information on a), b), C), see “Connecting to Video Equipment
With RGB or S-Video Inputs” on page 44.
VIDEO OUT
EXT CTRL
DC IN/
REMOTE
CCU
LENS
MENU FUNCTION DATA
UP
WHITE
BARS
RGB/SYNC
VBS
SCAN
DOWN
FREEZE
SOURCE
1
2
Set the MODE selector
to the “1” position.
If a CCMC cable is used, the S-video signal is also output from the
S-video output of the CMA-D2CE/D2MDCE
Sensor, switch, etc.
AC IN
CMA-D2CE/D2MDCE
camera adaptor