Desa SH-5597 User Manual

Page of 8
© 2006 DESA Specialty Products™ 
598-1162-01
D
UAL
B
RITE
®
 
Motion Sensor
Light Control
Model SH-5597
Features
•  D
UAL
Z
ONE
™ Technology.
•  Turns on lighting when motion is detected.
•  Automatically turns lighting off.
•  D
UAL
B
RITE
®
 Timer.
•  Photocell keeps the lighting off during daylight hours.
•  LED indicates motion was sensed (day or night).
2 Wire 
Connectors
Gasket
6 Screws
(3 sizes included)
Light Control
Requirements
•  The Light Control requires 120-volts AC.
•  If you want to use Manual Override, the control must 
be wired through a switch.
• 
Some  codes  require  installation  by  a  qualified 
electrician.
•  This product is intended for use with a junction box 
marked for use in wet locations.
Mounting Strap
Mounting Bolt
2 Lamps
(installed)
OPERATION
* resets to Auto Mode at dawn.
TEST
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to 
Dawn
D
UAL
B
RITE
®
Put  ON-TIME  switch 
on the sensor bottom 
to TEST and the D
UAL
-
B
RITE
®
 switch OFF.
MANUAL MODE
ON-TIME
TEST 
1 5 20
... back on.
AUTO
1 Second OFF 
then...
D
UAL
B
RITE
®
 TIMER
Light comes on half bright for selected time after dusk 
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the 
light turns on full bright for the ON-TIME (1, 5, or 20 
minutes) then returns to dim mode.
Move ON-TIME Switch to 
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off 
for one second then 
back on*
MANUAL MODE
AUTO
TEST
Note:   When first turned on wait about 1 
1
/
2
 minutes 
for the circuitry to calibrate.
Manual  mode  only  works  at  night 
because daylight returns the sensor 
to AUTO.
Flip the light switch off for one second 
then back on to toggle between AUTO 
and MANUAL MODE.
Manual  mode  works  only  with  the 
ON-TIME  switch  in  the  1,  5,  or  20 
position.
*  If you get confused while switching modes, turn the 
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Rubber Plug
Plastic Hanger
Cover 
Plate
Sensor
Lamp 
Holders
This package includes:
Put the ON-TIME switch in the 1, 
5, or 20 minute position.
Mode: 
On-Time: 
Works:  Day  Night
Test 
5 Sec 
 
x
Auto 
1, 5, 20 min. 
 
 
x
Manual 
Until Dawn* 
 
 
x