Desa SH-5597 User Manual

Page of 8
3
598-1162-01
 
 
Maximum
 
Maximum Range 
Coverage Angle
SPECIFICATIONS
Horizontal Range . . . . Up  to  70  ft.  (21  m);  100  ft. 
(30.5  m)  with  Range  Boost.  
[varies  with  surrounding 
temperature]
Vertical Range . . . . . . Up to 15 ft. (4.6 m)
Sensing Angle . . . . . . Up to 240° horizontal. Up to 80° 
Vertical
Electrical Load . . . . . . Up  to  200  Watt  Maximum  In-
candescent  [Up  to  100  Watt 
Maximum each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST,  AUTO,  and  MANUAL 
MODE
Time Delay  . . . . . . . . 1, 5, 20 minutes
D
UAL
B
RITE
®
 Timer . . . . 3, 6 hours, Dusk-to-Dawn
Replacement lamp . . . T4 100W, G8 halogen bi-pin 120 
VAC
DESA  Specialty  Products
  reserves  the  right  to  dis-
continue products and to change specifications at any 
time without incurring any obligation to incorporate new 
features in products previously sold.
MAX
MIN
RANGE
ON-TIME
DUAL BRITE™
TEST  1  5  20
MINUTES
OFF 3 6 DUSK TO
DAWN
HOUR
BO
O
S
T
 
Motion
Motion
15 ft. 
(4.6 m)
 
70 ft.  100 ft. 
 
(21 m)  (30.5 m)
 
 
Boosted
Sensor
The detector is less sensitive to motion directly towards it.
240°
D
UAL
Z
ONE
D
UAL
Z
ONE
D
UAL
Z
ONE
D
UAL
Z
ONE
NOTE: D
UAL
Z
ONE
™ is a new zone of detection which 
was added as an option to select Heath
®
/Zenith motion 
sensing products. This feature adds a zone of detec-
tion under the motion sensor. D
UAL
Z
ONE
™ requires 
no additional adjustment and operates in conjuction 
with the forward-looking sensor.
  Loosen the clamp screw in the 
sensor  ball  joint  and  gently 
rotate the sensor.
  Walk  through  the  coverage 
area  noting  where  you  are 
when the lights turn on (also, 
the LED will flash several times 
when motion is detected). Move 
the sensor head up, down, or 
sideways to change the cover-
age area. 
Keep the sensor at 
least 2" (2.5 cm) away from 
the lamps.
  Adjust the RANGE as needed. 
RANGE  set  too  high  may 
increase false triggering.
 
Secure the sensor head by 
tightening the clamp screw.
 
Do not overtighten the screw.
  Set the amount of TIME you want the lights to stay 
on after motion is detected (1, 5, or 20 minutes).
  Set the D
UAL
B
RITE
®
 switch to the  amount of time 
after dusk you want the lights on at low level (Off, 
3, 6 Hrs., Dusk-to-Dawn).
Clamp 
Screw
 
Ball 
Joint
Aim Sensor 
Down for Short 
Coverage
Aim Sensor 
Higher for Long 
Coverage
TEST AND ADJUSTMENT
 
Turn on the circuit breaker and light switch.
NOTE:  Sensor  has  a  1 
1
/
2
  minute  warm  up  period 
before it will detect motion. When first turned 
on, wait 1 
1
/
2
 minutes.
Bottom of Sensor
Avoid aiming the control at:
•  Objects  that  change  temperature  rapidly,  such  as 
heating  vents  and  air  conditioners.  These  heat 
sources could cause false triggering.
•  Areas where 
pets or traffic may trigger the control.
•  
Nearby large, light-colored objects reflecting light 
may trigger the shut-off feature. Do not point other 
lights at the sensor.
  Least Sensitive 
 Most Sensitive
  Turn  the  RANGE  control  to  the  mid  position, 
D
UAL
B
RITE
®
 to OFF and the ON-TIME control to the 
TEST position.