6 Appendix 
6.1 RS-485 Addressing and Connections 
 
The Philips ProBridge (CBR-PB2-PHILIPS) is not an addressable 
device and requires no user settings.  The device simply acts as an 
interpreter, translating the remote telemetry commands into a 
format useable by the P/T/Z controller. 
Each camera input, whether a fixed camera or a Pan/Tilt/Zoom (P/T/Z) unit, is 
connected to a Kalatel unit input.  The Kalatel unit has an RS-485 network 
address, and so does the P/T/Z camera receiver.  This address determines 
when the telemetry receiver responds to commands sent over the RS-485 
data line.  Consult the PTZ installation manual for specific instructions on 
setting these addresses. 
 
The CBR-PB2-PHILIPS can be used in conjunction with multiple 
Kalatel units, and/or keypads controlling the domes and the Kalatel 
units.  Since the ProBridge unit is a terminated device, care should 
be used when using this unit in a mixed application.   
 
The RS-485 network is a multi-drop wiring configuration of maximum length 
3,000 feet (1000 meters).  RJ45 cable and RJ45 connectors are used for 
most hookups (see the installation/connection diagram).  Some equipment 
manufactured by Kalatel may use flying leads, terminal blocks, or other types 
of connections. 
Most units have looping RS-485 network connectors.  Either socket can be 
used.  Do not use third-party RS-485 equipment without first consulting 
Kalatel Technical Support for information on compatibility with other Kalatel 
equipment. 
RS-485 Wire Specification 
#24 AWG, twisted pair with shield (2-wire). 
Less than 16 pF per foot, nominal. 
Less than 25 ohms per 100 foot, nominal. 
2-wire:  Belden 9842 
4-wire:  Belden 9844 
 