Philips 0150-0241B User Manual
Philips ProBridge 15 0150-0241B
RS485 Network Address
Camera Address
AutoDome Address
025
1 – 32
0769 – 0800
026
1 – 32
0801 – 0832
027
1 – 32
0833 – 0864
028
1 – 32
0865 – 0896
029
1 – 32
0897 – 0928
030
1 – 32
0929 – 0960
031
1 – 32
0961 – 0992
032
1 – 32
0993 – 1024
--
--
--
255
1 – 32
8129 – 8160
Philips AutoDome Addresses are calculated as follows:
Philips AutoDome Address = Camera Address + 32 X (Network Address – 1)
Philips Data Converter Unit Switch Setting
Set the switches on the LTC8780 as follows:
S101: Switches 1, 3, and 4 set to OFF. Switch 2 set to ON.
S102: Switches 1 –3 set on ON, switch 4 set to OFF.
See Philips LTC8780 manual for details.
6.3 Using Kalatel Keypads
Keyboards (CBR-KB3/J and KTD-405) are typically used to provide initial
configuration of the Philips AutoDome for setting addresses and presets.
configuration of the Philips AutoDome for setting addresses and presets.
In some specific cases keyboards may be used in conjunction with
the CBR-PB2-PHILIPS units where multiple Kalatel units are being
the CBR-PB2-PHILIPS units where multiple Kalatel units are being
controlled via one or more local Keyboard. Available keyboards
are only involved when an RS-485 is configured with CBR-KB2/J,
are only involved when an RS-485 is configured with CBR-KB2/J,
CBR-KB3/J and KTD-405 Keyboards. Please contact Technical
Support for additional instructions concerning these special
Support for additional instructions concerning these special
installations.
NOTE
NOTE