Program activation
For internal use only
 07/2010
4-6
DAKS OScAR-Pro-TT Dataimport-Tool, User Manual
  
  
  
BHB_DATAIMPORT_04.fm
The most important error messages during logon
4.6
The most important error messages during logon
The below list covers the most important  error messages that may appear during the 
logon:
Field
Description
Unable to set up TCP/IP connection to OScAR-
Pro-TT Server.
Among other reasons, this message may surface 
because:
you entered a wrong IP address or IP 
port
the attempt to connect was forestalled by 
a firewall on your local computer, on the 
computer used for OScAR-Pro-TT Serv-
er, or along the route
the application OScAR-Pro-TT Server is 
not active
The attempt of the OpenScape Alarm Response 
Professional to log on to OScAR-Pro-TT Server 
with the assigned user name failed because an-
other application is already logged on with this 
name.
The application is not enabled in the chipcard 
data of OScAR-Pro-TT Server.
If this message appears, verify that:
the OScAR-Pro server entered in OS-
cAR-Pro-TT Server is properly marked 
as primary connection
OScAR-Pro-TT Server has already been 
connected successfully at least once 
with the OScAR-Pro server (been ’on-
line’) 
you have acquired the application right-
fully and the chipcard of your OScAR-Pro 
server is equipped with the pertinent en-
abled information
Table 4-2
The most important fault messages during logon