INSTALLATION INSTRUCTIONS FOR HUNTER
CEILING FAN LIGHT KITS MODELS:
28343, 28344, 28345, 28405, 28406, 28407, 28408, 28982, 28983, 28984, 28985, 28986, 28987
28330, 28331, 28332, 28333, 28334, 28335, 28336, 28337, 28338, 28339, 28340, 28341, 28342
 WARNING
• To avoid possible electrical shock, before in-
stalling  light  fixtures,   disconnect  power  by
turning off the circuit breakers both to the
outlet box and to its associated wall switch
location. If you cannot lock the circuit break-
ers  in  the  off   position,   securely  f asten  a
prominent warning device, such as a tag, to
the service panel.
• C onnect house wiring to the fan before at-
taching the light fixture to the fan.
• All  wiring  must  be  in  accordance  with  na-
tional  and  local  electrical  codes  and  ANSI/
NFPA 70. If you are unfamiliar with wiring,
you should use a qualified electrician.
C AUTIONS
• Read entire text carefully before beginning in-
stallation and save these instructions.
• To reduce the risk of electrical shock, install
this light kit only on listed Hunter ceiling fan
models:  Cote D’ Azur , Custom Home 2 ,
Captiva
,  44”  Dominion , Designer’s Choice ,
ORBit
,  52”  Dominion , Marseille , Santa
Barbara
,  Belle Meade  &  Etruscan
STEP 1: REMOVING WIRING HARNESS
Before you can install the modular accessory light
kit, you must remove the wiring harness and its com-
ponents from the modular switch housing on the
fans listed above. You must then install the wiring
harness into the modular accessory light kit.
NOTE: Refer to Figure 1 for the steps listed below.
1. Locate the reversing switch and carefully remove
the two screws holding the reversing switch to
the switch housing. The reversing switch can now
be removed from the switch housing.
2. Remove the patented breakaway connector from
the fan pull chain.
3. Carefully loosen the bellmouth nut from the fan
pull chain and remove the fan pull chain switch
from the switch housing.
4. Locate and carefully remove the two capacitors
from the switch housing.
5. You have now disconnected the wiring harness
and its components from the switch housing and
are ready to install them into the modular acces-
sory light kit.
STEP 2: INSTALLING WIRING HARNESS
NOTE: Refer to Figure 1 for steps listed below.
1. Locate the two wires in the lower switch housing
labeled “ Connect Light Here”  or “ For Light Use” .
One will be white, the other black/white. Unscrew
the wire nuts counterclockwise to expose the bare
metal leads.
2. Locate the white wire and the black wire coming
from the light fixture.
Connect the black wire from the light fixture to
the black/white wire from the lower switch hous-
ing.
Connect the white wire from the light fixture to
the white wire from the lower switch housing.
To fasten the wires, twist the two bare leads to-
gether. Place a wire nut over the intertwined length
of wire and twist clockwise until tight.
Fan Speed
Switch
Capacitor
Reverse Switch
M ulti-wire Plug
Connection
Capacitor
Bellmouth Nut
M 3 Housing
A ssembly Screws
Light K it Lead W ires
and W ire Nuts
FIGURE 1