Air King 3C614D User Manual

Page of 4
20" WHOLE HOUSE WINDOW FAN
20" (50.8 cm) MODEL 3C614D/9166D
 
MODEL  
  3C614D/9166D
  SPEED  HIGH 
MED 
LOW
  CFM  
3560 
3120 
2510
  M
3
/s  
1.68 
1.47 
1.18
  RPM  
1600 
1450 
1100
  Amps   1.4 
1.2 
1.0
  Watts    170 
145 
115
  dB A 
 64 
57 
50
MODEL/MODELO/MODELE 3C614D/9166D
DESCRIPTION
The Air King® 20" (50.8 cm) Whole House Window Fan features three 
intake and three exhaust speeds. Fan will fit windows 27" (68.6 cm) to 
38" (96.5 cm) wide x 26-1/4" (67.3 cm) high. The adjustable side panels 
are designed to accommodate Fan mounting either inside or outside 
interior window trim. The 3-paddle Fan blade is driven by a permanently  
lubricated,  permanent  split  capacitor  motor  with  6'  (1.8  m),  18/3  cord 
set.
SPECIFICATIONS
Motor  ...................................... 120V, 50/60 Hz 
Blade diameter ....................... 20" (50.8 cm)
Speeds .................................... 3 Intake, 3 Exhaust
Control .................................... Rotary Switch
Approvals ................................ ETL Listed. Close mesh Fan guard
 
meets OSHA requirements.
GENERAL SAFETY INFORMATION
When  using  electrical  appliances,  basic  precau-
tions should always be followed to reduce the risk 
of fire, electric shock and injury to person, includ-
ing the following:
1.  Read all instructions before using Fan.  
2.  Make certain that the power source conforms to the electrical 
requirements of the Fan.
3.  Use this Fan only as described in this manual.  Any other use 
not recommended by the manufacturer may cause fire, electrical 
shock, or injury to persons.
4.  Unplug power cord before installing, servicing, or moving the 
Fan.
WARNING:
 
DO  NOT  DEPEND  UPON  THE  ON-OFF 
SWITCH  AS  THE  SOLE  MEANS  OF  DISCONNECTING 
POWER  WHEN  INSTALLING  OR  SERVICING  THE  FAN.  
ALWAYS UNPLUG THE POWER CORD.
5.  This  Fan  must  NOT  be  used  in  potentially  dangerous 
locations such as flammable, explosive, chemical-laden 
or wet atmospheres.
6. The power cord is equipped with a three-prong grounded plug 
that must be inserted into a matching receptacle.  Under no 
circumstances must the grounding prong be cut off the plug.  
Where a two-prong wall receptacle is encountered, it must be 
replaced with a properly grounded three-prong receptacle in-
stalled in accordance with the National Electrical Code (NEC) 
and all applicable local codes and ordinances.  This work must 
be done only by a qualified electrician, using copper wire only. 
Contact your Grainger Distributor.
WARNING:
 USE OF A THREE-PRONG TO TWO-PRONG 
ADAPTER IS NOT RECOMMENDED.  IMPROPER CONNEC-
TION MAY CREATE THE RISK OF ELECTROCUTION.  USE 
OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
7.  Where possible, avoid the use of extension cords.  If they must 
be used, minimize the risk of overheating by ensuring that they 
are UL listed.  Never use a single extension cord to operate 
more than one Fan.
8.  Do  not  operate  any  Fan  with  a  damaged  cord  or  plug  or 
after  the  Fan  malfunctions,  has  been  dropped  or  damaged 
in any manner.  Return Fan to authorized service facility for 
examination, electrical or mechanical adjustment or repair.
9.  Do not insert or allow fingers or foreign objects to enter any 
ventilation or exhaust opening as it may cause an electric shock 
or fire, or damage the Fan.  Do not block or tamper with the 
Fan in any manner while it is in operation. 
10.Always  place  the  Fan  on  a  stable,  flat,  level  surface  when 
operating, to avoid the chance of the Fan overturning.  Locate 
the Power Cord so the Fan or other objects are not resting on it.  
Do not run Power Cord under carpeting.  Do not cover Power 
Cord with throw rugs, runners, or the like.  Arrange Power Cord 
away from room traffic and where it will not be tripped over.
11.This  Fan  is  not  intended  for  use  in  wet  or  damp  locations.  
Never locate a Fan where it may fall into a bathtub or other 
water container.
12. Do not use Fan outdoors.
13.This Fan is not suitable for use in agricultural facilities including 
areas where livestock, poultry or other animals are confined. 
Please  refer  to  National  Electric  Code  (NEC)  Article  547-7 
(2008), or applicable state or local codes or standards relating 
to electrical requirements for Agricultural Buildings. THIS FAN 
DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 
547-7 (2008).
14. This Fan is not suitable for use in hazardous locations. Please 
refer to National Electric Code (NEC) Article 500 or applicable 
state  or  local  codes  or  standards  relating  to  electrical 
requirements for Hazardous locations. THIS FAN DOES NOT 
MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).
WARNING:
 
REDUCE THE RISK OF FIRE OR 
ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY 
SOLID STATE SPEED CONTROL DEVICES.
SAVE THESE INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE-
SCRIBED.  PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.  FAILURE TO COMPLY 
WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
 RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.  
OPERATING INSTRUCTIONS & PARTS MANUAL
Rev. J 12/07
8
2085109A
Rev. J 12/07
1
2085109A
+
+
+
+
0
1
2
3
20
2
21
12
11
10
20
9
8
7
22
5
19
4
3
2
1
17
LISTE DES PIECES DE REMPLACEMENT
Clé 
No de Pièce 
Description 
Qte
  1 
02030113 
Moteur Assemblage 
1
  2 
2090008 
Vis #8 x 1,27 cm de type PPH 25 ZP 
24
  3 
05097110CG  Grille intérieure 
1
  4 
5090045 
Vis #10-32 x 1,27 cm HWH Serr F-ZP 
3
  5 
5082090CH 
Lame 
1
  7 
2010722 
Bâti 
1
  8 
05097100CG  Grille extérieure 
1
  9 
02084613 
Plaque centrale 
1
  10 
2060087 
Panneau latéral 
2
  11 
02090508 
Guide en caoutchouc 
4
  12 
2060086 
Canal 
2
  17 
05010109 
Bouton de l’interrupteur 
1
  19 
5090044 
Vis de réglage 0,64 cm 28 x 0,95 cm 
1
  20 
2091413 
Vis à bois #8 x 1,91 cm 
4
  21 
2084076 
Gabarit 
1
  22 
2090024 
Vis #8 x 1,91 cm PPH de type 25 ZP 
4