Windsor 10052300 User Manual

Page of 33
MACHINE TROUBLESHOOTING 
CUTTER 24V (SCE)   86037020   04/04/07 
4-14  
 
 
PROBLEM 
CAUSE 
SOLUTION 
Poor or no water pick-up 
Squeegee out of 
adjustment 
Adjust squeegee 
  
Debris caught on squeegee
Remove debris 
  
Worn squeegee blades 
Rotate or replace squeegee 
blades 
  
Vacuum hose clogged 
Clear obstruction from hose 
  
Vacuum hose disconnected 
from squeegee or recovery 
tank 
Reconnect vacuum hose 
  
Vacuum hose damaged 
Replace vacuum hose 
  
Recovery tank not sealed 
Place recovery tank dome on 
tank.  Replace damaged 
gaskets. 
  
Foam filling recovery tank 
Empty recovery tank 
Use less or different detergent 
Use defoamer 
Vacuum motor does not run, or 
runs slowly 
Recovery tank full 
Drain recovery tank 
  
Recovery tank float system 
dirty 
Clean float system 
  
Circuit breaker tripped 
Reset circuit breaker 
  
Loose connection 
Check motor wires and 
connections 
  
Faulty vacuum switch 
Replace switch 
 
Worn vacuum motor 
brushes 
Replace brushes, check 
commutator 
Poor scrubbing performance 
Debris caught in scrub 
brushes 
Remove debris 
 
Worn brushes or pads 
Replace brushes or pads 
 
Improper detergent, brush 
or pad used 
Contact equipment or 
application specialist 
 
Low scrub brush down 
pressure 
Increase brush pressure 
 
Low battery charge 
Charge batteries 
Brush motors do not run, or runs 
slowly 
Circuit breaker(s) tripped 
Reset circuit breaker(s) 
 
Loose connection 
Check motor wires and 
connection 
 
Faulty brush motor 
contactor 
Replace contactor 
 
Worn brush motor brushes 
Replace brushes, check 
commutator