Windsor 10052300 User Manual

Page of 33
MACHINE TROUBLESHOOTING 
 
CUTTER 24V (SCE)   86037020   04/04/07 
4-15 
 
PROBLEM 
CAUSE 
SOLUTION 
Little or no solution flow to the floor 
Solution tank empty 
Fill solution tank 
  
Solution flow turned off or 
set too low 
Turn on or increase flow 
setting 
  
Solution strainer plugged 
Clean solution strainer 
  
Solution hoses obstructed 
Clear obstruction from 
hose 
  
Solution solenoid valve 
obstructed or stuck 
Clean or replace 
  
Vent hole in solution tank 
lid obstructed 
Clear obstruction from vent 
hole 
No power to machine 
Battery disconnected 
Check all battery cable 
connections 
  
Emergency shut-off 
activated (If included) 
Reset 
  
Battery connections 
corroded 
Clean connections 
  
Faulty main contactor 
Replace contactor 
  
Faulty key switch 
Replace switch 
Little or no propel 
Low battery charge 
Charge batteries 
 
Wheels spin 
Decrease brush pressure 
 
Controller overheated 
Allow cool down period 
Adjust brush shroud if 
needed 
 
Loose connection 
Check motor wires and 
connection