MAINTENANCE 
CMPS  86290230  02/22/07 
 
1. FLOAT 
SHUT-OFF 
The float shut-off is located inside the 
recovery tank.  The purpose of the float 
shut-off is to notify the user that the 
recovery tank is full.  Remove daily and 
clean any debris for maximum airflow.   
 
2. STRAINER 
The strainer is located on the lower right 
side between the front and rear wheels.  
The strainer protects the check valve and 
pump from debris.  If there is little or no 
solution flow to the ground, check the 
stainer for debris.  Drain the solution tank 
and clean the solution strainer.  To remove 
the strainer, turn the bottom part of the 
strainer counterclockwise until the bottom is 
separated.  Clean out the debris from the 
wire mesh and reassemble.  Make sure the 
o-ring gasket is in place when reassembled. 
 
3. CIRCUIT 
BREAKERS 
Circuit breakers interrupt the flow of power 
in the event of an electrical overload.  When 
a circuit breaker is tripped, reset it by 
pressing the exposed button.  If a circuit 
breaker continues to trip, the cause of the 
electrical overload should be found and 
corrected. 
 
4-2  
6 Amp.  Protects the pump 
motor. 
 
 
10 Amp.  Protects the vacuum 
motor.